Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/13104
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorGarcía Rentería, Francisco Fernando-
dc.contributor.authorPalacio Tobón, Carlos Alberto-
dc.date.accessioned2020-01-13T22:52:10Z-
dc.date.available2020-01-13T22:52:10Z-
dc.date.issued2011-
dc.identifier.citationDe Luque, M., García Rentería, F. F., y Palacio Tobón, C. A. (2011). Determinación del T90 en la bahía de Santa Marta (Col.). DYNA. 77(167), 122-131.spa
dc.identifier.issn0012-7353-
dc.identifier.urihttp://hdl.handle.net/10495/13104-
dc.description.abstractRESUMEN: Se investigó la tasa de decaimiento de Escherichia coli (E. coli) cuando las aguas residuales domésticas son descargadas al océano por medio de un sistema de emisario submarino, para ello se examinó la relación de tres (3) factores naturales (intensidad de luz, salinidad y proporción volumétrica de la mezcla de agua residual y agua marina) con la tasa de decaimiento bacterial, empleando un diseño experimental compuesto central rotable con diferentes combinaciones de los factores antes mencionados. Bajo cada combinación de los factores, la concentración de E. coli fue medida al inicio de cada experimento y cada media hora en un periodo total de dos (2) horas. Los resultados de la experimentación fueron analizados estadísticamente mediante una regresión paso a paso que permitió relacionar estos factores con la variable respuesta (la tasa de decaimiento de E. coli). Se desarrolló una herramienta en Matlab para encontrar la tasa de decaimiento de E. coli de acuerdo a los resultados de la experimentación. Esta herramienta se utilizó para predecir el tiempo de desaparición bacteriano (T90) según las condiciones de vertimiento del emisario submarino de Santa Marta. En su aplicación se encontró una tasa de decaimiento de 0.00357 min-1 para el fondo, 0.01066 min-1 para profundidades medias y 0.01388 min-1 para la superfi cie del océano, igualmente se estimaron valores de T90 de 283 min, 94 min y 72 min. respectivamente.spa
dc.description.abstractABSTARCT: In this study was founded the Escherichia coli (E. coli) die-off rate when wastewater are discharged into the ocean through submarine outfall of Santa Marta. The relationship between three natural factors (light intensity, salinity and volumetric mixing ratio of seawater and wastewater) and the die-off rate was examined. The experiments were performed based on rotatable central composite designs with different factor level combinations of three factors mentioned before. Under each factor level combinations, the quantity of E. coli was measured Mat the beginning of each experiment and every half hour later on during two (2) consecutive hours. The experiments results were statistically analyzed through a stepwise regression that allowed link these factors with the output variable (E. coli die-off rate). It was created a tool in matlab in order to found the E. coli die-off rate according to the experiments results. The tool was used to predict the bacterial die-off time (T90) for the Submarine outfall discharges in the Santa Marta Bay (Colombia). In the application the die-off rate results were 0.00357 min-1 in deep, 0.01066 min-1 for medium deeps and 0.01388 min-1 on the surface, as well the T90 values were estimated 283 min, 94 min y 72 min respectively.spa
dc.format.extent9spa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.publisherUniversidad Nacional de Colombia, Facultad de Minas, Centro de Publicacionesspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia*
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/*
dc.subjectEmisario submarino-
dc.subjectTasa de decaimiento E. Coli-
dc.subjectT90-
dc.subjectE. coli-
dc.subjectDiseño experimental compuesto central rotativo-
dc.titleDeterminación del T90 en la bahía de Santa Marta (Col.)spa
dc.title.alternativeT90 determination at Santa Marta bay (Col.)spa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGrupo de Ingeniería y Gestión Ambiental (GIGA)spa
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn2346-2183-
oaire.citationtitleDYNAspa
oaire.citationstartpage122spa
oaire.citationendpage131spa
oaire.citationvolume78spa
oaire.citationissue167spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-nd/4.0/spa
dc.publisher.placeMedellín, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.relation.ispartofjournalabbrevDynaspa
Aparece en las colecciones: Artículos de Revista en Ingeniería

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
PalacioCarlos_2011_DeterminaciónT90Bahia.pdfArtículo de investigación242.56 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons