Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/21375
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorCampuzano Zuluaga, Germán-
dc.contributor.authorÁlvarez Sánchez, Luis Gonzalo-
dc.contributor.authorEscobar Gallo, Gloria Elcy-
dc.contributor.authorRíos Orrego, Alexandra Marcela-
dc.contributor.authorPabón Vidal, Adriana Lucía-
dc.contributor.authorMiranda Arboleda, Andrés Felipe-
dc.contributor.authorBlair Trujillo, Silvia-
dc.contributor.authorCampuzano Maya, Germán-
dc.date.accessioned2021-08-01T13:20:43Z-
dc.date.available2021-08-01T13:20:43Z-
dc.date.issued2010-
dc.identifier.citationCampuzano-Zuluaga, G., Álvarez-Sánchez, G., Escobar-Gallo, G. E., Valencia-Zuluaga, L. M., Ríos-Orrego, A. M., Pabón-Vidal, A., Miranda-Arboleda, A. F., Blair-Trujillo, S., & Campuzano-Maya, G. (2010). Design of Malaria Diagnostic Criteria for the Sysmex XE-2100 Hematology Analyzer, The American Society of Tropical Medicine and Hygiene, 82(3), 402-411. Retrieved Aug 1, 2021, from https://www.ajtmh.org/view/journals/tpmd/82/3/article-p402.xmlspa
dc.identifier.issn0002-9637-
dc.identifier.urihttp://hdl.handle.net/10495/21375-
dc.description.abstractAbstract: Thick film, the standard diagnostic procedure for malaria, is not always ordered promptly. A failsafe diagnostic strategy using an XE-2100 analyzer is proposed, and for this strategy, malaria diagnostic models for the XE-2100 were developed and tested for accuracy. Two hundred eighty-one samples were distributed into Plasmodium vivax, P. falciparum, and acute febrile syndrome groups for model construction. Model validation was performed using 60% of malaria cases and a composite control group of samples from AFS and healthy participants from endemic and non-endemic regions. For P. vivax, two observer-dependent models (accuracy = 95.3–96.9%), one non–observer-dependent model using built-in variables (accuracy = 94.7%), and one non–observer-dependent model using new and built-in variables (accuracy = 96.8%) were developed. For P. falciparum, two non–observer-dependent models (accuracies = 85% and 89%) were developed. These models could be used by health personnel or be integrated as a malaria alarm for the XE-2100 to prompt early malaria microscopic diagnosis.spa
dc.format.extent10spa
dc.format.mimetypeapplication/pdfspa
dc.language.isoengspa
dc.publisherAmerican Society of Tropical Medicine and Hygienespa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by/2.5/co/*
dc.titleDesign of Malaria Diagnostic Criteria for the Sysmex XE-2100 Hematology Analyzerspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGrupo Malariaspa
dc.identifier.doihttps://doi.org/10.4269/ajtmh.2010.09-0464-
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn1476-1645-
oaire.citationtitleAmerican Journal of Tropical Medicine and Hygienespa
oaire.citationstartpage402spa
oaire.citationendpage411spa
oaire.citationvolume82spa
oaire.citationissue3spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by/4.0/spa
dc.publisher.placeBaltimore, Estados Unidosspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.subject.decsMalaria-
dc.subject.decsDiagnóstico-
dc.subject.decsDiagnosis-
dc.subject.decsPlasmodium vivax-
dc.description.researchgroupidCOL0007524spa
dc.relation.ispartofjournalabbrevAm. J. Trop. Med. Hyg.spa
Aparece en las colecciones: Artículos de Revista en Ciencias Médicas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
CampuzanoGerman_2010_MalariaSysmexHematology.pdfArtículo de investigación2.31 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons