Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/10495/23338
Título : | Un nuevo prototipo de stent biliar cubierto (flower stent) frente al stent biliar convencional en la prevención de pancreatitis y colecistitis poststent |
Otros títulos : | Comparison of Flower Petal Stenting, a new prototype of covered biliary stent, with conventional biliary stenting for prevention of pancreatitis and post-stent cholecystitis |
Autor : | Castaño Llano, Rodrigo Álvarez, Óscar Kyun Lee, Jong Lopera, Jorge Calvo Betancur, Víctor Daniel |
metadata.dc.subject.*: | Colecistitis Cholecystitis Pancreatitis Stents Metálicos Autoexpandibles Self Expandable Metallic Stents Conductos Biliares Bile Ducts |
Fecha de publicación : | 2018 |
Editorial : | Asociación Colombiana de Gastroenterología |
Resumen : | RESUMEN: Antecedentes y objetivos: la pancreatitis y la colecistitis son complicaciones mayores después de la postura de un stent metálico cubierto en el manejo de la obstrucción biliar distal maligna. Se pretende comparar el uso de un stent biliar cubierto convencional con un nuevo prototipo de stent biliar cubierto de morfología en flor con baja fuerza axial (FA) y fuerza radial (FR), y evaluar el impacto de las cifras de colecistitis y pancreatitis poststent. Métodos: se realizó un estudio prospectivo no aleatorizado en el que se comparó un
grupo de 18 pacientes con stent biliar tipo flor (SF) con un grupo de pacientes que recibieron un stent biliar
convencional (SC) con una relación 1:2, para el manejo de la obstrucción biliar distal maligna. Se evaluaron
datos demográficos; el éxito técnico y clínico; así como la aparición de colecistitis y/o pancreatitis, tasas de
migración y/u oclusión. Resultados: se evaluaron 18 pacientes en el grupo con SF (7 hombres, 39 %) con
una edad mediana de 72 años y 36 pacientes (16 hombres, 44 %) en el grupo de SC con una edad mediana
de 71 años. Se presentaron 3 casos de colecistitis y 4 casos de pancreatitis, todos ellos en el grupo de
SC. Al explorar la asociación de los aspectos clínicos con respecto al tipo de stent, el análisis multivariado
mostró diferencias estadísticamente significativas en 4 aspectos: la hemoglobina, la longitud de estenosis,
la etiología y la oclusión del stent. Al evaluar los tiempos de supervivencia entre los pacientes con SC y SF,
no se hallaron diferencias significativas en las funciones de supervivencia (log rank, p = 0,399). En el modelo
de riesgos proporcionales de Cox, solo un aspecto mostró diferencias significativas frente a los tiempos de
supervivencia: la presencia de metástasis. Conclusiones: el uso de un nuevo prototipo de stent SF (con
surcos laterales) con menor FA y FR se relaciona con un menor índice de complicaciones como colecistitis
y pancreatitis en comparación con el SC, en la paliación de las estenosis biliares malignas distales sin detri-
mento de su permeabilidad o migración y sin afectar la supervivencia de estos pacientes. ABSTRACT: Background and objectives: Pancreatitis and cholecystitis are major complications following stenting with covered metallic stents to manage malignant distal biliary obstructions. We compare the use of a conventional covered biliary stent with a new prototype of a covered biliary stent with a flower-pedal structure that uses with low axial force and radial force in order to evaluate impacts on cholecystitis and pancreatitis after stenting. Methods: This is a non-randomized prospective comparison of a group of 18 patients stented with a flowerlike biliary stent (FS group) with a group of 36 patients who received conventional biliary stents (CS group) ratio for management of malignant distal biliary obstructions. Demographic data and data about technical and clinical success including the appearance of cholecystitis and/or pancreatitis, migration rates and/or occlusion were evaluated. Results: The 18 FS group patients included 7 men (39%) and had a median age of 72 years. The 36 CS group patients included 16 men (44%) and had a median age of 71 years. There were three cases of cholecystitis and four cases of pancreatitis, all of which were in the CS group. Multivariate analysis showed statistically significant differences between the two groups in four clinical areas: hemoglobin, length of stenosis, etiology and occlusion of stents. No significant differences were found in survival time functions (Log Rank, p = 0.399). In Cox’s proportional hazards model, the only significant difference with respect to survival times was found on the issue of whether or not metastasis was present. Conclusions: The use of the new prototype flower-like biliary stent with lateral grooves and lower axial force and radial force is related to a lower rate of complications such as cholecystitis and pancreatitis than the use of conventional stents for palliation of distal malignant biliary stenoses. The new stent has no detriments in terms of permeability or migration and did not affect the survival of these patients. |
metadata.dc.identifier.eissn: | 2500-7440 |
ISSN : | 0120-9957 |
metadata.dc.identifier.doi: | 10.22516/25007440.312 |
Aparece en las colecciones: | Artículos de Revista en Ciencias Médicas |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
RodrigoCastaño_2018_PrototipoStentBiliar.pdf | Artículo de investigación | 1.73 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons