Título : | Transferencia de impulsos y ganancia de tensión en transformadores monofásicos de baja potencia |
Otros títulos : | Impulse transfer and voltage gain in single phase low power transformers |
Autor : | Velilla Hernández, Esteban Muñoz Balvin, John Ever Ramírez Londoño, Edwar Alejandro Valencia Velásquez, Jaime Alejandro |
metadata.dc.subject.*: | Funciones de transferencia Transfer functions Generadores de impulsos Pulse generators Distribución de energía eléctrica-alta tensión Electric power distribution - high tension Transformador monofásico |
Fecha de publicación : | 2012 |
Editorial : | Centro de Información Tecnológica |
Resumen : | RESUMEN: Se evaluó la transferencia de impulsos de tensión 1.2/50μs y 3/23μs del primario al secundario, en tres transformadores monofásicos utilizados en aplicaciones electrónicas, uno de 18W, otro de 85W y un autotransformador de 50W, considerándolos en vacío y con carga resistiva en el secundario. El autotransformador fue el que presentó mayor amortiguamiento y menor valor máximo en el impulso transferido. La máxima transferencia de tensión ocurrió en vacío y se analizaron las respuestas en frecuencia de la ganancia de tensión de los transformadores en vacío entre 10Hz y 1MHz, ajustándolas a funciones de transferencia para modelar la transferencia de impulsos de tensión. La confrontación de los resultados experimentales y teóricos tanto en el dominio del tiempo como en el dominio de la frecuencia, mostraron información valiosa sobre la transferencia de los impulsos de tensión en los transformadores monofásicos. ABSTRACT: The voltage impulse transferences of 1.2/50μs and 3/23μs from the primary to the secondary winding was tested in three single phase transformers used in electronic applications; two transformers of 85W and 18W, and one autotransformer of 50W were used under no load and under resistive load conditions. The autotransformer showed higher damping and lower peak value in the transferred voltage impulse than the other transformers. The maximum voltage value in the secondary winding was obtained at no load condition and the frequency response of the voltage gain of the transformers between 10Hz and 1MHz were analyzed and fitted to transfer functions to model the voltage impulse transferences. The comparison of experimental results with those obtained from transfer functions in the frequency and time domain provides valuable information about the transferred voltage impulses in single phase transformers. |
metadata.dc.identifier.eissn: | 0718-0764 |
ISSN : | 0716-8756 |
metadata.dc.identifier.doi: | 10.4067/S0718-07642012000100009 |
Aparece en las colecciones: | Artículos de Revista en Ingeniería |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
VelillaEsteban_2012_ImpulsosGananciaTension.pdf | Artículo de investigación | 735.15 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.