dc.description.abstractRESUMEN : La amputación de miembro inferior es una problemática a la que se enfrentan muchas personas a nivel mundial, sin embargo, en Colombia este número se ve acrecentado por los heridos que han dejado las minas antipersonales. Además de la perdida de una extremidad, los pacientes sufren en otros ámbitos como el psicológico, social y laboral, provocando así una baja calidad de vida. Para mejorar su situación, una gran ayuda es el uso de prótesis, aunque, muchos pacientes no presentan buena adherencia a ellas. Por esto es necesario generar estrategias que motiven a las personas con amputación a continuar con el proceso de rehabilitación y a usar su prótesis. Con esto en mente, el grupo de investigación GIBIC está desarrollando una estrategia que consiste en usar una bicicleta horizontal en conexión con juego serio de realidad virtual. Dicho proyecto, ya ha tenido tres fases previas donde se determinaron los requisitos que debía cumplir el sistema, incluyendo la medición de variables cinéticas, cinemáticas y fisiológicas, que posteriormente se enviaran al juego. Sin embargo, era indispensable que estas mediciones fueran correspondientes a lo que sucedía en la realidad, para evitar ciber mareos en los usuarios. Por esta razón el presente trabajo tenía como fin, verificar la integridad y coherencia de los datos y señales adquiridos por los sistemas de medición. Y según los resultados obtenidos, se puede decir, que el sistema puede empezar con pruebas en conexión con el juego, aunque se deben hacer algunos ajustes, principalmente en la medición de variables fisiológicas.spa
dc.description.abstractABSTRACT : The lower limb amputation is a problem faced by many people worldwide, however, in Colombia this number is increased by the injuries caused by anti-personnel landmines. In addition to the loss of a limb, patients also suffer in other areas such as psychological, social, and occupational, thus causing a low-quality life. To improve their situation, a great help is the use of prostheses, although many patients do not have good adherence to them. For this reason, it is necessary to generate strategies that motivate people with amputation to continue with the rehabilitation process and to use their prosthesis. With this in mind, the GIBIC research group is developing a strategy that consists of using a horizontal bike in connection with serious game with virtual reality. This project already has three previous phases in which the requirements to be met by the system were determined, including the measurement of kinetic, kinematic, and physiological variables, which will be sent to the game. However, it was essential that these measurements should correspond to what was actually happening, in order to avoid cybersickness among users. For this reason, the purpose of this paper was to verify the integrity and coherence of the data and signals acquired by the measurement systems. And according to the results obtained, it can be said that the system could start with tests in connection with the game, although some adjustments must be made, mainly in the measurement of physiological variables.spa
dc.format.extent89spa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.type.hasversioninfo:eu-repo/semantics/draftspa
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/2.5/co/*
dc.titleVerificación de la integridad de los datos adquiridos por un sistema de medición de variables cinéticas, cinemáticas y fisiológicas, ajustado a una bicicleta horizontal en conexión con un juego seriospa
dc.typeinfo:eu-repo/semantics/bachelorThesisspa
dc.publisher.groupGrupo de Investigación en Bioinstrumentación e Ingeniería Clínica (GIBIC)spa
oaire.versionhttp://purl.org/coar/version/c_b1a7d7d4d402bccespa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
thesis.degree.nameBioingenierospa
thesis.degree.levelPregradospa
thesis.degree.disciplineFacultad de Ingeniería. Bioingenieríaspa
thesis.degree.grantorUniversidad de Antioquiaspa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-sa/4.0/spa
dc.publisher.placeMedellínspa
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1fspa
dc.type.redcolhttps://purl.org/redcol/resource_type/TPspa
dc.type.localTesis/Trabajo de grado - Monografía - Pregradospa
dc.subject.decsEquipos y Suministros de Hospitales-
dc.subject.decsEquipment and Supplies, Hospital-
dc.subject.decsinstrumentación-
dc.subject.decsinstrumentation-
dc.subject.lembAmputación de las piernas-
dc.subject.lembRehabilitación de amputados-
dc.subject.lembProtesis-
dc.subject.proposalcorrespondencia de datosspa
dc.subject.proposalmedición de variables.spa
Aparece en las colecciones: Bioingeniería

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
CaroSantiago_2022_VerificaciónMediciónBicicleta.pdfTrabajo de grado de pregrado7.83 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons