Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/26227
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorMejía Londoño, Juliana-
dc.contributor.authorMontoya Ochoa, Francisco Javier-
dc.contributor.authorGutiérrez Rua, Alejandra-
dc.contributor.authorMacías Rueda, Cristian-
dc.contributor.authorLópez Granada, Jaime-
dc.contributor.authorDonado Gómez, Jorge Hernando-
dc.date.accessioned2022-02-26T20:59:58Z-
dc.date.available2022-02-26T20:59:58Z-
dc.date.issued2007-
dc.identifier.citationMejía Londoño J, Montoya Ochoa FJ, Gutiérrez Rua A, Macías Rueda C, López Granada J, Donado Gómez JH. Suplemento de oxígeno peri-operatorio e infección del sitio operatorio: meta-análisis de ensayos clínicos controlados. Med UPB [Internet]. 15 de diciembre de 2007 [citado 26 de febrero de 2022];26(2):127-36. Disponible en: https://revistas.upb.edu.co/index.php/medicina/article/view/2281spa
dc.identifier.issn0120-4874-
dc.identifier.urihttp://hdl.handle.net/10495/26227-
dc.description.abstractRESUMEN: Objetivo: revisar sistemáticamente la evidencia acerca de la eficacia del suplemento de dosis altas de oxígeno perioperatorio y el riesgo de infección del sitio operatorio. Fuentes de datos: Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, LILACS, CINAHL, contacto con investigadores, libros. Selección estudios: ensayos clínicos aleatorios o cuasialeatorios que evaluaran suplemento con oxígeno a dosis altas FIO2 ≥ 80% durante el transoperatorio y al menos dos horas postoperatorias con dosis estándares de oxígeno FIO2≤35% y evaluaran la infección del sitio operatorio superficial al menos a los 15 días postoperatorio.Extracción datos: los autores extrajeron los datos en forma independiente y evaluaron la calidad de los estudios con la escala de Jadad.Síntesis datos: Se incluyeron cuatro estudios con 989 participantes. La infección del sitio operatorio con la administración de FIO2 alta tuvo un OR 0,79 IC 95% (0,34, 1,84) valor p = 0,58 y con evidencia de heterogeneidad X2 11,77 gl 3, p = 0.008, I2 74,5%. Sobre la mortalidad el OR 0,17 IC 95% (0,03, 0,98) Valor p = 0,05 y sin evidencia de heterogeneidad X2 0,01 gl 1, p = 0,94, I2 0%. La duración de la hospitalización tuvo una WMD 0,75 IC 95% (0,05, 1,45)) Valor p = 0,03 y sin evidencia de heterogeneidad X2 2,74 gl 2, p = 0,25, I2 26,9%.Conclusiones: los resultados no apoyan el uso de FIO2 altas en el manejo de pacientes electivos con cirugía abdominal para reducir la infección del sitio operatorio y sugiere que puede disminuir la mortalidad global.spa
dc.description.abstractABSTRACT: Objective: To systematically asses the evidence about high perioperatory oxygen doses efficacy and the surgical wound infection risk.Data Sources: The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, LILACS, CINAHL, investigators contacts, books.Selection Criteria: Randomized Controlled Trials which asses the oxygen high doses FIO2 ≥ 80% supplement during the transoperatory and at least two hours postoperatory with standard oxygen doses FIO2≤ 35% and evaluate the superficial surgical site infection at least fifteen days after surgery. Data Collection and Analysis: The authors extracted the data in an independent way and evaluated the trials quality with the Jadad scale.Main Results: Four trial involving 989 participants were included in this review. The administration of high FIO2 demonstrated no statistically significant reduction in the surgical site infection development. OR 0,79 IC 95% (0,34, 1,84) p value = 0,58 and with heterogeneity evidence X2 11,77 gl 3, p value = 0,008, I2 74,5%. On mortality OR 0,17 IC 95% (0,03, 0,98) p value = 0,05 and without heterogeneity evidence X2 0,01 gl 1, p value = 0,94, I2 0%. Hospital length of stay had a WMD 0,75 IC 95% (0,05, 1,45)) p value = 0,03 and without heterogeneity evidenced X2 2,74 gl 2, p = 0,25, I2 26,9%.Conclusions: Results don’t support the use of high FIO2 in the management of electives patients whit abdominal surgery to reduce the surgical site infection and suggest it can reduce the global mortality.spa
dc.format.extent10spa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.publisherUniversidad Pontificia Bolivariana, Facultad de Medicinaspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/*
dc.titleSuplemento de oxígeno peri-operatorio e infección del sitio operatorio : meta-análisis de ensayos clínicos controladosspa
dc.title.alternativePerioperatory oxygen supplement and surgical wound infection : a meta-nalysis of randomized controlled trialsspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGrupo Académico de Epidemiología Clínicaspa
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn2357-6308-
oaire.citationtitleMedicina U.P.B.spa
oaire.citationstartpage127spa
oaire.citationendpage136spa
oaire.citationvolume26spa
oaire.citationissue2spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-nd/4.0/spa
dc.publisher.placeMedellín, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.subject.decsOxígeno-
dc.subject.decsOxygen-
dc.subject.decsOxígeno - administración y dosificación-
dc.subject.decsOxygen - administration y dosage-
dc.subject.decsCuidados Preoperatorios-
dc.subject.decsPreoperative Care-
dc.subject.decsRiesgo-
dc.subject.decsRisk-
dc.subject.decsInfección de la Herida Quirúrgica-
dc.subject.decsSurgical Wound Infection-
dc.subject.proposalprevención y controlspa
dc.identifier.urlhttps://revistas.upb.edu.co/index.php/medicina/article/view/2281spa
dc.description.researchgroupidCOL0007121spa
dc.relation.ispartofjournalabbrevMed. U.P.B.spa
Aparece en las colecciones: Artículos de Revista en Ciencias Médicas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
MejíaJuliana_2007_OxigenoAdministracionydosificacionCuidadospreoperatorios.pdfArtículo de investigación142.53 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons