Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/35263
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorBalparda Arias, Jon Kepa-
dc.contributor.authorGallo Villegas, Jaime Alberto-
dc.contributor.authorMcEwen Ochoa, Juan Guillermo-
dc.contributor.authorOchoa Múnera, Juan Eugenio-
dc.contributor.authorAristizábal Ocampo, Dagnóvar-
dc.date.accessioned2023-06-02T15:34:59Z-
dc.date.available2023-06-02T15:34:59Z-
dc.date.issued2012-
dc.identifier.citationBalparda, J.K., Gallo, J., McEwen, J.G., Ochoa, J.E., & Aristizábal, D. (2012). Evaluación hemodinámica no invasiva con cardiografía de impedancia: aplicaciones en falla cardíaca y en hipertensión arterial Non-invasive hemodynamic evaluation with impedance cardiography: applications in heart failure and hypertension.spa
dc.identifier.issn0120-5633-
dc.identifier.urihttps://hdl.handle.net/10495/35263-
dc.description.abstractRESUMEN: La cardiografía de impendancia (CGI) representa un método no invasivo para la evaluación del es-tado hemodinámico latido a latido. Aunque se introdujo por primera vez hace más de 40 años, la CGI ha mostrado un resurgimiento en la última década, a partir de una serie de estudios clínicos que han demostrado su precisión en la estimación del volumen latido, tanto contra el “gold-standard“ invasivo (termodilución), como contra los métodos de referencia no invasivos (ecocardiografía). Diversos estu-dios demuestran la utilidad de esta técnica en el manejo del paciente con falla cardíaca y en el enfoque diagnóstico y terapéutico de la hipertensión arterial, por lo cual constituyen actualmente dos de las aplicaciones clínicas más importantes de la CGI. En falla cardiaca, los cambios en el volumen de líquido del tórax y del gasto cardíaco evaluados por CGI, han demostrado ser predictores de descompensación aguda, incluso semanas antes del inicio de la sintomatología respiratoria; además, permiten identifi car el origen cardiogénico o respiratorio de la disnea cuando el examen físico y los demás paraclínicos no son concluyentes. En los pacientes con hipertensión arterial no controlada o resistente, la CGI permite realizar una mejor caracterización del fenotipo hipertensivo y elegir la estrategia farmacológica más es-pecífi ca para intervenir la alteración hemodinámica predominante (resistencia vascular vs. gasto cardiaco elevado). En este artículo se realiza una revisión de los principios biofísicos de la CGI y su utilidad en la evaluación no invasiva del estado hemodinámico, así como una evaluación crítica de la literatura que da soporte a su aplicación clínica en el tratamiento de la falla cardíaca y la hipertensión arterial.spa
dc.description.abstractABSTRACT: Impedance cardiography (ICG) represents a non-invasive method for hemodynamic assessment in a beat-to-beat basis. Since its introduction more than forty years ago, a renewed interest in the use of this technique during the last decade has been noticed, mainly as a result of a series of clinical studies showing its precision in the estimation of stroke volume either against invasive gold standard (i.e. thermodilution) or against non-invasive reference methods (i.e. echocardiography). On the other hand, ICG has demonstrated to be useful for the management of heart failure patients and for the diagnostic and therapeutic approach to hypertension, which currently constitute two of the major applications of ICG. In heart failure patients, changes in thoracic fluid content and cardiac output tracked by ICG have shown to be predictors of acute decompensation even weeks before respiratory symptoms appear; also allowing identification of a cardiac vs. respiratory origin of dyspnea when physical examination and laboratory tests are not conclusive. In the particular case of patients with uncontrolled or severe hypertension, ICG makes possible a better characterization of hypertensive phenotype leading to a more specific choice of pharmacological agents to treat the primary hemodynamic alteration (i.e elevated peripheral resistance vs. elevated cardiac output). The present review, provides a review of the biophysical principles of ICG and its precision in measuring stroke volume and present a critical assessment of the literature supporting its clinical application in the management of heart failure and arterial hypertension.spa
dc.format.extent9spa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.publisherSociedad Colombiana de Cardiología y Cirugía Cardiovascularspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/*
dc.titleEvaluación hemodinámica no invasiva con cardiografía de impedancia: aplicaciones en falla cardíaca y en hipertensión arterialspa
dc.title.alternativeNon-Invasive Hemodynamic Evaluation with Impedance Cardiography: Applications in Heart Failure and Hypertensionspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupBiología Celular y Molecular CIB U. de A. U. del Rosariospa
dc.publisher.groupGrupo de Investigación en Medicina Aplicada a la Actividad Física y el Deporte (GRINMADE)spa
dc.identifier.doi10.1016/S0120-5633(12)70111-0-
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn2357-3260-
oaire.citationtitleRevista Colombiana de Cardiologíaspa
oaire.citationstartpage82spa
oaire.citationendpage90spa
oaire.citationvolume19spa
oaire.citationissue2spa
thesis.degree.disciplinesin facultad - programaspa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-nd/4.0/spa
dc.publisher.placeBogotá, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_dcae04bcspa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTREVspa
dc.type.localArtículo de revisiónspa
dc.subject.decsCardiography, Impedance-
dc.subject.decsCardiografía de Impedancia-
dc.subject.decsHemodynamics-
dc.subject.decsHemodinámica-
dc.subject.decsInsuficiencia Cardíaca-
dc.subject.decsHeart Failure-
dc.subject.decsHipertensión-
dc.subject.decsHypertension-
dc.subject.proposalEstado hemodinámicospa
dc.description.researchgroupidCOL0000962spa
dc.description.researchgroupidCOL0070223spa
dc.relation.ispartofjournalabbrevRev. Colomb. Cardiol.spa
Aparece en las colecciones: Artículos de Revista en Ciencias Médicas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
BalpardaJon_2012_EvaluaciónHemodinámicaCardiografía.pdfArtículo de revisión273.6 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons