Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/38008
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorCampuzano Zuluaga, Germán-
dc.contributor.authorGrobusch, Martin-
dc.contributor.authorHänscheid, Thomas-
dc.date.accessioned2024-02-04T15:28:18Z-
dc.date.available2024-02-04T15:28:18Z-
dc.date.issued2010-
dc.identifier.citationCampuzano-Zuluaga, G., Hänscheid, T. & Grobusch, M.P. Automated haematology analysis to diagnose malaria. Malar J 9, 346 (2010). https://doi.org/10.1186/1475-2875-9-346spa
dc.identifier.issn1475-2875-
dc.identifier.urihttps://hdl.handle.net/10495/38008-
dc.description.abstractABSTRACT: For more than a decade, flow cytometry-based automated haematology analysers have been studied for malaria diagnosis. Although current haematology analysers are not specifically designed to detect malaria-related abnormalities, most studies have found sensitivities that comply with WHO malaria-diagnostic guidelines, i.e. ≥ 95% in samples with > 100 parasites/μl. Establishing a correct and early malaria diagnosis is a prerequisite for an adequate treatment and to minimizing adverse outcomes. Expert light microscopy remains the 'gold standard' for malaria diagnosis in most clinical settings. However, it requires an explicit request from clinicians and has variable accuracy. Malaria diagnosis with flow cytometry-based haematology analysers could become an important adjuvant diagnostic tool in the routine laboratory work-up of febrile patients in or returning from malaria-endemic regions. Haematology analysers so far studied for malaria diagnosis are the Cell-Dyn®, Coulter® GEN· S and LH 750, and the Sysmex XE-2100® analysers. For Cell-Dyn analysers, abnormal depolarization events mainly in the lobularity/granularity and other scatter-plots, and various reticulocyte abnormalities have shown overall sensitivities and specificities of 49% to 97% and 61% to 100%, respectively. For the Coulter analysers, a 'malaria factor' using the monocyte and lymphocyte size standard deviations obtained by impedance detection has shown overall sensitivities and specificities of 82% to 98% and 72% to 94%, respectively. For the XE-2100, abnormal patterns in the DIFF, WBC/BASO, and RET-EXT scatter-plots, and pseudoeosinophilia and other abnormal haematological variables have been described, and multivariate diagnostic models have been designed with overall sensitivities and specificities of 86% to 97% and 81% to 98%, respectively. The accuracy for malaria diagnosis may vary according to species, parasite load, immunity and clinical context where the method is applied. Future developments in new haematology analysers such as considerably simplified, robust and inexpensive devices for malaria detection fitted with an automatically generated alert could improve the detection capacity of these instruments and potentially expand their clinical utility in malaria diagnosis.spa
dc.format.extent15spa
dc.format.mimetypeapplication/pdfspa
dc.language.isoengspa
dc.publisherBMC (BioMed Central)spa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/2.5/co/*
dc.titleAutomated haematology analysis to diagnose malariaspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGrupo Malariaspa
dc.identifier.doi10.1186/1475-2875-9-346-
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
oaire.citationtitleMalaria Journalspa
oaire.citationstartpage1spa
oaire.citationendpage15spa
oaire.citationvolume9spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-sa/4.0/spa
dc.publisher.placeLondres, Inglaterraspa
dc.type.coarhttp://purl.org/coar/resource_type/c_dcae04bcspa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTREVspa
dc.type.localArtículo de revisiónspa
dc.subject.decsMalaria-
dc.subject.decsAutomatización - métodos-
dc.subject.decsAutomation - methods-
dc.subject.decsSangre - parasitología-
dc.subject.decsBlood - parasitology-
dc.subject.decsCitometría de Flujo - métodos-
dc.subject.decsFlow Cytometry - methods-
dc.subject.decsParasitología - métodos-
dc.subject.decsParasitology - methods-
dc.subject.decsPlasmodium - aislamiento y purificación-
dc.subject.decsPlasmodium - isolation and purification-
dc.subject.decsSensibilidad y Especificidad-
dc.subject.decsSensitivity and Specificity-
dc.description.researchgroupidCOL0007524spa
dc.subject.meshurihttps://id.nlm.nih.gov/mesh/D008288-
dc.subject.meshurihttps://id.nlm.nih.gov/mesh/D001331-
dc.subject.meshurihttps://id.nlm.nih.gov/mesh/D001769-
dc.subject.meshurihttps://id.nlm.nih.gov/mesh/D005434-
dc.subject.meshurihttps://id.nlm.nih.gov/mesh/D010274-
dc.subject.meshurihttps://id.nlm.nih.gov/mesh/D010961-
dc.subject.meshurihttps://id.nlm.nih.gov/mesh/D012680-
dc.relation.ispartofjournalabbrevMalar. J.spa
Aparece en las colecciones: Artículos de Revista en Ciencias Médicas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
CampuzanoGerman_2010_MalariaAutomatedhaematologyAnalysis.pdfArtículo de investigación1.52 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons