dc.contributor.author | Carmona Fonseca, Jaime | - |
dc.date.accessioned | 2024-03-23T15:55:05Z | - |
dc.date.available | 2024-03-23T15:55:05Z | - |
dc.date.issued | 2007 | - |
dc.identifier.citation | Carmona-Fonseca J. Colinesterasas en sangre total medidas con técnica semicuantitativa y en eritrocitos o plasma medidas con técnicas cuantitativas: relaciones. biomedica [Internet]. 1 de junio de 2007 [citado 11 de diciembre de 2023];27(2):244-56. Disponible en: https://revistabiomedica.org/index.php/biomedica/article/view/220 | spa |
dc.identifier.issn | 0120-4157 | - |
dc.identifier.uri | https://hdl.handle.net/10495/38666 | - |
dc.description.abstract | RESUMEN: Introducción. Se necesita un modelo que permita convertir valores de colinesterasa obtenidos con la técnica Lovibond® (semicuantitativa para sangre total) en cifras equivalentes en las técnicas Michel, EQM® y Monotest® (cuantitativas eritrocitarias y plasmáticas). Objetivo. Examinar la relación entre Lovibond® (técnicas tintométrica de Edson y de Limperos y Ranta) y las técnicas cuantitativas. Materiales y métodos. Diseño descriptivo, transversal, prospectivo, con dos muestras representativas de poblaciones laborales de 18 a 59 años, sin exposición a plaguicidas inhibidores de colinesterasa, vinculadas al Seguro Social en el valle de Aburrá y en el cercano oriente antioqueño. Resultados. Se evaluaron 827 trabajadores. Según la técnica Lovibond® se clasificaron en cuatro categorías: 821 con valores de 75% o más de actividad colinesterásica (categorías 75%, 87,5% y 100%) y otros seis con actividad inferior a 75%. Con cada técnica cuantitativa los valores promedios de colinesterasa eritrocitaria y plasmática correspondientes a los cuatro valores de Lovibond® fueron estadísticamente diferentes entre sí. Los promedios de cada técnica cuantitativa fueron mayores a medida que creció el valor de la técnica semicuantitativa. Con Lovibond® se clasificó muy mal (61%-73%) la baja actividad enzimática eritrocitaria, pero la clasificación de la baja actividad plasmática fue absolutamente errónea (94%-96%). Conclusión. Es posible estimar en forma adecuada los valores de colinesterasa eritrocitaria o plasmática que corresponden a las técnicas de Michel y EQM® a partir de datos de la técnica Lovibond® y viceversa, pero sólo cuando la actividad colinesterásica es normal, pues Lovibond® tiene una capacidad muy deficiente para identificar como “bajos” los valores que realmente lo son según las pruebas cuantitativas. | spa |
dc.description.abstract | ABSTRACT: Introduction. An equivalence model which allows comparison of blood cholinesterase values, measured by Lovibond® (semiquantitative technique), and Michel, EQM®, Monotest® (erythrocyte and plasma cholinesterases) values measured by quantitative techniques is required. Objective. The performance of Lovibond® (Edson tintometric and Limperos & Ranta techniques) were compared with quantitative techniques. Materials and methods. The experimental design was descriptive, cross-sectional, and prospective. From a working population (18-59 years) in Valle de Aburrá and Near East of Antioquia. 827 representative samples were chosen for their lack of exposure to cholinesterase- inhibiting plaguicides and affiliated to the Social Security System. Results. (1) 827 workers were classified by Lovibond® in four categories: 821 values with 75% of cholinesterase activity or greater (categories 75, 87.5 and 100%) and 6 with cholinesterase activity smaller than 75%. (2) With each quantitative method, the mean values of erythrocyte and plasmatic cholinesterase corresponding to the four values obtained with Lovibond® were statistically different to each other. (3) The mean values of each quantitative technique increased when increased the tintometric method value. (4) Lovibond® classified the low enzymatic erythrocyte activity very poorly (61-73%), but the classification of the low enzymatic plasma activity was almost completely in error (94-96%). Conclusion. The values of erythrocyte or plasma cholinesterase were adequately estimated by both the quantitative techniques of Michel and EQM® and by Lovibond, but only when the enzymatic activity is normal. Lovibond® , however, had a poor capacity to designate as “low” the values that were low according to the quantitative tests. | spa |
dc.format.extent | 13 páginas | spa |
dc.format.mimetype | application/pdf | spa |
dc.language.iso | spa | spa |
dc.publisher | Instituto Nacional de Salud | spa |
dc.type.hasversion | info:eu-repo/semantics/publishedVersion | spa |
dc.rights | info:eu-repo/semantics/openAccess | spa |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/2.5/co/ | * |
dc.title | Colinesterasas en sangre total medidas con técnica semicuantitativa y en eritrocitos o plasma medidas con técnicas cuantitativas: relaciones | spa |
dc.title.alternative | Cholinesterases in total blood measured with a semiquantitative technique, and plasma or erythrocyte cholinesterases measured with quantitative techniques | spa |
dc.type | info:eu-repo/semantics/article | spa |
dc.publisher.group | Grupo Malaria | spa |
dc.publisher.group | Salud y Comunidad | spa |
dc.identifier.doi | 10.7705/biomedica.v27i2.220 | - |
oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | spa |
dc.rights.accessrights | http://purl.org/coar/access_right/c_abf2 | spa |
dc.identifier.eissn | 2590-7379 | - |
oaire.citationtitle | Biomédica | spa |
oaire.citationstartpage | 244 | spa |
oaire.citationendpage | 256 | spa |
oaire.citationvolume | 27 | spa |
oaire.citationissue | 2 | spa |
dc.rights.creativecommons | https://creativecommons.org/licenses/by-nc-nd/4.0/ | spa |
dc.publisher.place | Bogotá, Colombia | spa |
dc.type.coar | http://purl.org/coar/resource_type/c_2df8fbb1 | spa |
dc.type.redcol | https://purl.org/redcol/resource_type/ART | spa |
dc.type.local | Artículo de investigación | spa |
dc.subject.decs | Inhibidores de la Colinesterasa | - |
dc.subject.decs | Cholinesterase Inhibitors | - |
dc.subject.decs | Análisis Químico de la Sangre | - |
dc.subject.decs | Blood Chemical Analysis | - |
dc.subject.decs | Colinesterasas | - |
dc.subject.decs | Cholinesterases | - |
dc.subject.decs | Eritrocitos - enzimología | - |
dc.subject.decs | Erythrocytes - enzymology | - |
dc.subject.decs | Plaguicidas | - |
dc.subject.decs | Pesticides | - |
dc.subject.decs | Acetilcolinesterasa | - |
dc.subject.decs | Acetylcholinesterase | - |
dc.subject.decs | Monitoreo Epidemiológico | - |
dc.subject.decs | Epidemiological Monitoring | - |
dc.subject.decs | Butirilcolinesterasa | - |
dc.subject.decs | Butyrylcholinesterase | - |
dc.subject.decs | Compuestos Organofosforados | - |
dc.subject.decs | Organophosphorus Compounds | - |
dc.description.researchgroupid | COL0007524 | spa |
dc.description.researchgroupid | COL0047449 | spa |
dc.subject.meshuri | https://id.nlm.nih.gov/mesh/D002800 | - |
dc.subject.meshuri | https://id.nlm.nih.gov/mesh/D001774 | - |
dc.subject.meshuri | https://id.nlm.nih.gov/mesh/D002802 | - |
dc.subject.meshuri | https://id.nlm.nih.gov/mesh/D004912 | - |
dc.subject.meshuri | https://id.nlm.nih.gov/mesh/D000110 | - |
dc.subject.meshuri | https://id.nlm.nih.gov/mesh/D010575 | - |
dc.subject.meshuri | https://id.nlm.nih.gov/mesh/D062665 | - |
dc.subject.meshuri | https://id.nlm.nih.gov/mesh/D002091 | - |
dc.subject.meshuri | https://id.nlm.nih.gov/mesh/D009943 | - |
dc.relation.ispartofjournalabbrev | Biomédica | spa |
Aparece en las colecciones: | Artículos de Revista en Ciencias Médicas |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
CarmonaJaime_2007_Colinesterasas_Sangre_Medidas.pdf | Artículo de investigación | 164.16 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons