Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/38928
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMuñoz Ortega, Isabel Cristina-
dc.contributor.authorMontañez Becerra, Ana María-
dc.date.accessioned2024-04-05T21:42:19Z-
dc.date.available2024-04-05T21:42:19Z-
dc.date.issued2024-
dc.identifier.urihttps://hdl.handle.net/10495/38928-
dc.description.abstractRESUMEN : La empresa Prótesis Avanzadas comercializa prótesis mioeléctricas de miembro superior que cuentan con movimientos independientes para cada dedo, actuados a partir de una señal de PWM enviada desde un microcontrolador; donde los comandos de apertura y cierre son controlados mediante temporizadores en el microcontrolador. El presente proyecto comprende el diseño electrónico y la programación de un nuevo sistema de control que integra realimentación de la posición de los dedos, permitiendo una calibración automática y continua. Para lograr este objetivo se identificaron sensores que pudieran ubicarse en la prótesis actual sin afectar sus dimensiones, entre los cuales un potenciómetro engranado con el resto del mecanismo fue seleccionado como la solución definitiva. A partir de este sistema se propuso y validó un sistema de detección de posición y calibración automático para la apertura y cierre de un dedo. Se realizaron pruebas de fatiga al sistema comprendiendo 4000 ciclos de apertura y cierre, a partir de lo cual se validó la estabilidad de la medición y la durabilidad del sistema. Para implementar el sistema en los demás dedos de la mano se realizó el diseño electrónico de una nueva tarjeta electrónica para la prótesis, actualizando también el microcontrolador por un ESP32 y los puentes H por un modelo más pequeño y nuevo. Por último, se desarrollaron las funciones de sincronización de los dedos permitiendo la determinación automática de PWM y temporizadores que aseguren un movimiento coordinado de estos. Como trabajo a futuro se propone la implementación del sistema para las otras funcionalidades de la mano y la realización de pruebas con usuarios.spa
dc.description.abstractABSTRACT : The company Prótesis Avanzadas commercializes myoelectric upper limb prostheses featuring independent movements for each finger, actuated by a PWM signal sent from a microcontroller. The opening and closing commands are controlled through timers on the microcontroller. The present project involves the electronic design and programming of a new control system that integrates feedback of finger positions, allowing for automatic and continuous calibration. To achieve this objective, sensors were identified that could be placed in the current prosthesis without affecting its dimensions, among which a geared potentiometer integrated with the rest of the mechanism was selected as the definitive solution. Using this system, a proposal for an automatic position detection and calibration system for finger opening and closing was suggested and validated. Fatigue tests were conducted on the system, comprising 4000 cycles of opening and closing, confirming the stability of the measurement and the durability of the system. To implement the system in the other fingers of the hand, the electronic design of a new electronic board for the prosthesis was carried out, also upgrading the microcontroller to an ESP32 and the H-bridges to a smaller and newer model. Finally, synchronization functions for the fingers were developed, allowing for the automatic determination of PWM and timers to ensure coordinated movement. As future work, the implementation of the system for other hand functionalities and user testing is proposed.spa
dc.format.extent47 Páginasspa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.type.hasversioninfo:eu-repo/semantics/draftspa
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.titleDesarrollo de un sistema de retroalimentación de la posición y el movimiento de los dedos para la prótesis de A3D de Prótesis Avanzadasspa
dc.typeinfo:eu-repo/semantics/bachelorThesisspa
oaire.versionhttp://purl.org/coar/version/c_b1a7d7d4d402bccespa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
thesis.degree.nameBioingenieraspa
thesis.degree.levelPregradospa
thesis.degree.disciplineFacultad de Ingeniería. Bioingenieríaspa
thesis.degree.grantorUniversidad de Antioquiaspa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-sa/4.0/spa
dc.publisher.placeMedellín, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1fspa
dc.type.redcolhttps://purl.org/redcol/resource_type/TPspa
dc.type.localTesis/Trabajo de grado - Monografía - Pregradospa
dc.subject.decsDiseño de Prótesis-
dc.subject.decsProsthesis Design-
dc.subject.decsElectromiografía-
dc.subject.decsElectromyography-
dc.subject.decsMateriales Inteligentes-
dc.subject.decsSmart Materials-
dc.subject.meshurihttps://id.nlm.nih.gov/mesh/D011474-
dc.subject.meshurihttps://id.nlm.nih.gov/mesh/D004576-
dc.subject.meshurihttps://id.nlm.nih.gov/mesh/D000080745-
Aparece en las colecciones: Bioingeniería

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
MontanezAna_2024_DesarrolloSistemaRetroalimentación.pdfTrabajo de grado de pregrado1.43 MBAdobe PDFVisualizar/Abrir
Anexo.zipAnexo136.32 kBUnknownVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.