Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/10495/40623
Título : | Cost-effective Sieverts-type apparatus for the study of hydrogen storage in materials |
Autor : | Gómez Vélez, Alejandro Osorio Cortínez, Joan Santiago Zuleta Gil, Alejandro Alberto Vargas Ramírez, Andrés Felipe Ramírez Sánchez, Carolina Tamayo Sepúlveda, José Adrián Correa Bedoya, Esteban Echavarria Isaza, Adriana Ostos Ortíz, Carlos Bolivar Osorio, Francisco Javier Echeverría Echeverría, Félix |
metadata.dc.contributor.conferencename: | World Hydrogen Energy Conference (24 : del 23 al 27 de junio de 2024 : Cancún, México) |
Fecha de publicación : | 26-jun-2024 |
Resumen : | ABSTRACT: In the context of climate change in which the planet finds itself, hydrogen is one of the energy carriers with the greatest potential, and therefore the most studied, to replace hydrocarbons. However, its large-scale implementation has not been possible mainly due to problems in its storage. The most used techniques do not have a large capacity, and involve extreme operating conditions, which makes technologies such as solid-state storage in materials, where higher capacities are achieved at moderate operating conditions, an alternative to consider, and where the most prominent are metal hydrides, borohydrides and alanates, although they can have long kinetic times(Abe et al., 2019; Millet, 2014; Schlapbach & Züttel, 2001; Schneemann et al., 2018; Tarhan & Çil, 2021). To evaluate the performance of this type of materials there are two techniques, gravimetric and manometric, where, depending on the variable that is recorded, weight and pressure respectively, the amount of hydrogen stored or released at certain conditions of temperature and pressure can be calculated. However, in general, the manometric technique is usually the most widely used, since it is considered sufficiently robust and the necessary equipment, known as Sieverts, is cheaper. However, this equipment is still quite expensive commercially and with generic performance, and that is why many research groups worldwide have developed equipment based on this technique, with better performance and which are usually cheaper(Blach & Gray, 2007; Carrillo et al., 2018; Pyle et al., 2017). Considering that hydrogen storage is a line of research that is gaining more and more weight in Colombia and Latin America. It is necessary to have this type of equipment to evaluate the materials developed, in such a way that they are accessible to research groups in the region, without this implying a loss of range or accuracy in the measurement. For this reason, this work presents the design (Figure 1) and construction (Figure 2) of an economic, portable and semi-automatic Sieverts type apparatus, with an approximate cost of 8,000 USD, and which, with at least 160 mg of material, is capable of accurately performing the typical tests performed on these materials, PCI curves, kinetic curves and cyclic behavior curves; at temperatures up to 773K and pressures from 0.01 MPa to 10MPa. |
Aparece en las colecciones: | Documentos de conferencias en Ingeniería |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
GomezAlejandro_2024_Cost-effective_Sieverts-type.pptx | Documento de conferencia | 4.49 MB | Microsoft Powerpoint XML | Visualizar/Abrir |
GomezAlejandro_2024_Cost-effective_Sieverts-type.pdf | Documento de conferencia | 222.15 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons