Escudo Universidad de Antioquia

Sistema de Bibliotecas

Universidad de Antioquia

Repositorio Institucional UdeA


Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10495/4961
Título : Carga inmediata sobre implante único : estudio clínico prospectivo
Otros títulos : Immediate load in single-tooth restorations : a clinical prospective study
Autor : Arango B., Paola Andrea
Porras Salas, Andrés Felipe
Arismendi Echavarría, Jorge Alberto
Palabras clave : Implantes de titanio
Carga inmediata
Estabilidad primaria
Torque de inserción
Fecha de publicación : 2009
Editorial : Universidad de Antioquia, Facultad de Odontología
Citación : Arango PA, Porras AF, Arismendi JA. Carga inmediata sobre implante único: estudio clínico prospectivo. Rev Fac Odontol Univ Antioq. 2009; 21(1): 6-15
Resumen: Introducción: la carga inmediata se ha convertido en una alternativa viable de tratamiento que ofrece múltiples beneficios a los pacientes como función y estética inmediata, reducción del trauma quirúrgico y disminución del tiempo total de tratamiento. Se hizo un estudio prospectivo controlado para la colocación de implantes en casos clínicos de restauración de diente único que recogiese el consenso propuesto en la literatura para evaluar el éxito clínico bajo el protocolo de carga inmediata: implantes de conexión interna, cónicos, de superficie texturizada y un mínimo de 32 Ncm de torque inicial. Métodos: se colocaron 21 implantes Renova® (Lifecore Biomedical Inc., Chaska, MN) en 17 pacientes adultos (6 hombres y 11 mujeres) rango de edad entre 18 y 74 años, sistémicamente sanos con necesidad de reemplazo de diente único en sectores anterior y premolar de ambos maxilares. Resultados: la tasa de éxito acumulativa a 18 meses fue de 95,2%. Se obtuvieron valores de éxito similares a los reportados con el protocolo de carga convencional y se encontró correlación directa entre la distancia desde el hueso al punto de contacto y el porcentaje de presencia de papila en el espacio interproximal. Conclusión: los resultados indican que el protocolo de carga inmediata para el tratamiento de restauraciones de diente único en la zona anterior mediante implantes temporalizados inmediatamente, sin función oclusal, es una alternativa viable con tasas de éxitos mayores al 95%, comparables a las logradas con el protocolo de carga convencional.
Abstract : Introduction: immediate loading of implants has become a viable treatment alternative that offers multiple benefits for patients such as providing immediate function and esthetics, reduction of surgical trauma and less treatment time. A controlled prospective clinical trial was conducted to evaluate the success of immediately loaded implants for single-tooth restoration following consensus protocols in recent literature. Methods: twenty-one 3.75 x 13mm RBM-treated surface internal connection implants (Renova®, Lifecore Biomedical Inc., Chaska Mn.) were placed in 17 systemically healthy patients (6 males, 11 females), ages between 18 and 74 years who required single-tooth replacement in the anterior and premolar regions of both jaws. Results: the 18-month cumulative success rate for this study was 95.2%. According to the statistical analysis in this study, immediate loading of implants for single-tooth restoration compares favorably to the two-stage protocol and a direct correlation between the distance from bone to contact point and papilla filling was found. Conclusions: results from the present study indicate that the single-tooth restoration in the anterior area with immediately loaded surface-treated threaded titanium implants and no occlusal function is a viable treatment alternative with a success rate greater than 95%, comparable to the conventional loading protocol.
Grupo de INV. : Grupo de Investigación en Patología Oral, Periodoncia y Cirugía Alvéolo-Dentaria (POPCAD)
URI : http://hdl.handle.net/10495/4961
ISSN : 0121246X
21457670 E
Aparece en las colecciones: CIFO (Centro de Investigaciones de la Facultad de Odontología)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
ArangoPaola_2009_CargaImplanteUnico.pdfArtículo de Revista416 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

 


Unidad de Gestión Tecnológica /Sistema de Bibliotecas / Universidad de Antioquia / Cl. 67 Nº 53 - 108 - Bloque 8 Conmutador: 219 51 51- 219 51 40 comunicacionessistemadebibliotecas@udea.edu.co Medellín - Colombia