Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/4972
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorArismendi Echavarría, Jorge Alberto-
dc.contributor.authorMesa Jaramillo, Ana Lucía-
dc.contributor.authorGarcía López, Luz Piedad-
dc.contributor.authorSalgado Agudelo, Juan Fernando-
dc.contributor.authorCastaño Granada, María Catalina-
dc.contributor.authorMejía Bravo, Richard Milton-
dc.date.accessioned2016-10-09T14:53:24Z-
dc.date.available2016-10-09T14:53:24Z-
dc.date.issued2010-
dc.identifier.citationArismendi JA, Mesa AL, García LP, Salgado JF, Castaño C, Mejía R. Estudio comparativo de implantes de superficie lisa y rugosa. Resultados a 36 meses. Rev Fac Odontol Univ Antioq. 2010; 21(2): 159-169spa
dc.identifier.issn0121-246X-
dc.identifier.urihttp://hdl.handle.net/10495/4972-
dc.description.abstractABSTRACT: The implant surface affects the clinical response in terms of osseointegration and should be evaluated in the long term. In the last years, literature has strongly recommended the use of modifiedspa
dc.description.abstractRESUMEN: La estabilidad primaria es esencial para una oseointegración ideal y depende de las características micro- y macroscópicas del implante. Las características superficiales de un implante influyen de manera importante en la respuesta clínica en términos de oseointegración y sus resultados deben evaluarse a largo plazo. En la literatura se discute sobre los beneficios de utilizar implantes de superficie rugosa para mejorar la oseointegración. El objetivo de este estudio fue evaluar la oseointegración de dos grupos de implantes, uno de superficie lisa o maquinada y otro de superficie rugosa o modificada. Métodos: se efectuó seguimiento clínico y radiográfico a 12, 24 y 36 meses a dos grupos de implantes de conexión externa, tipo tornillo, de la casa comercial Lifecore®, uno con 30 implantes de superficie lisa (SuperCAT®) y otro con 30 implantes de superficie rugosa (RBM®). Las mediciones a 12, 24 y 36 meses de función fueron comparadas entre sí para determinar el comportamiento de la cresta ósea marginal utilizando la plataforma del implante como referencia. Resultados: en los implantes de superficie lisa a los 24 y 36 meses, la pérdida promedio de altura de la cresta ósea fue 1,5mm. En los implantes de superficie rugosa a los 24 meses la pérdida ósea promedio fue 1,4mm, y a los 36 meses fue 1,5mm en promedio. Conclusiones: el seguimiento clínico y radiográfico de dos grupos de implantes con superficies diferentes no presentó diferencias estadísticamente significativas en cuanto a las variables evaluadas, para casos de restauración de diente único sobre implantes.surface implants, in order to improve osseointegration. The primary stability is essential to obtain osseointegration and it depends on the micro and macro characteristics of the implant and bone structure. The usage of active surfaces is an advantage, but it does not modify the bone density. The aim of this study is to undertake a clinical and radiographic evaluation between two different groups of implants, machined versus modified surfaces. Methods: a 24 to 36 months clinical and radiographic follow-up was done to two groups of Lifecore® implants, one group with 30 machined implants (Super CAT®), and the other one with 30 modified surface (RBM®) external hex connection and screw type implants. Measurements were taken to determine the bone crest behavior using the implant platform as reference at 24-36 months of function and were compared with the 12 months measurements. Results: in machined implants at 24-36 months, the average marginal bone loss was 1.5 mm. In modified surface implants at 24 months, the average marginal bone loss was 1.4 mm, and at 36 months, the loss was 1.5 mm. Conclusions: there are no statistical significant differences between the two groups of machined and modified implant surface, for single tooth restoration, as it relates to clinical and radiographic follow up.spa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.publisherUniversidad de Antioquia, Facultad de Odontologíaspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsAtribución-NoComercial-CompartirIgual 2.5 Colombia (CC BY-NC-SA 2.5 CO)*
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/2.5/co/*
dc.subjectOseointegración-
dc.subjectImplantes-
dc.subjectTitanio-
dc.titleEstudio comparativo de implantes de superficie lisa y rugosa. Resultados a 36 mesesspa
dc.title.alternativeMachined versus rough surface implants, a clinical study. 36-month follow-upspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGrupo de Investigación en Patología Oral, Periodoncia y Cirugía Alvéolo-Dentaria (POPCAD)spa
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn2145-7670-
oaire.citationtitleRevista Facultad de Odontología Universidad de Antioquiaspa
oaire.citationstartpage159spa
oaire.citationendpage169spa
oaire.citationvolume21spa
oaire.citationissue2spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-sa/4.0/spa
dc.publisher.placeMedellín, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.relation.ispartofjournalabbrevRev Fac Odontol Univ Antioqspa
Aparece en las colecciones: Artículos de Revista en Odontología

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
ArismendiJorge_2010_EstudioImplantesLisaRugosa.pdfArtículo de investigación587.6 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons