Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/5448
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorArias Suárez, Sandra Liliana-
dc.contributor.authorEcheverry Rendón, Mónica-
dc.contributor.authorRobledo Restrepo, Sara María-
dc.contributor.authorArismendi Echavarría, Jorge Alberto-
dc.contributor.authorEscobar Sierra, Diana Marcela-
dc.contributor.authorOssa Orozco, Claudia Patricia-
dc.contributor.authorPavón Palacio, Juan José-
dc.date.accessioned2016-11-18T21:44:54Z-
dc.date.available2016-11-18T21:44:54Z-
dc.date.issued2013-
dc.identifier.citationS. L. Arias et al., "Procesamiento, caracterización y ensayos biológicos de titanio modificado electroquímicamente para implantes dentales", Rev. Fac. Ing. Univ. Antioquia, no. 69, pp. 96-108, 2013.spa
dc.identifier.issn0120-6230-
dc.identifier.urihttp://hdl.handle.net/10495/5448-
dc.description.abstractRESUMEN: Las aplicaciones biomédicas del titanio y sus aleaciones son posibles debido a que éste material posee características deseables para el reemplazo de huesos, incluyendo buenas propiedades mecánicas, excelente resistencia a la corrosión y alta biocompatibilidad. Sin embargo, una de sus principales limitaciones radica en el encapsulamiento del material por un delgado tejido fibroso, el cual puede estar relacionado con el aflojamiento del implante. Como una alternativa para dar solución a esta limitación, en el presente trabajo se realizaron modificaciones químicas y electroquímicas a la superficie del titanio para evaluar su influencia en la oseointegración de los implantes, para lo cual se realizaron ensayos in vitro del material en contacto con osteoblastos. Los resultados de caracterización por microscopía electrónica de barrido (SEM), de medición de parámetros de rugosidad y de morfología de los osteoblastos, indicaron que existe una relación entre la rugosidad superficial y la adhesión de las células óseas. Las superficies con los mayores parámetros verticales de rugosidad, para las condiciones evaluadas, permitieron una mejor adhesión celular. Estos resultados sugieren que la combinación de técnicas químicas y electroquímicas puede permitir el control de la rugosidad de los implantes dentales de titanio y, por tanto, la optimización de su oseointegración.spa
dc.description.abstractABSTRACT: Biomedical applications of titanium and its alloys are possible due to their suitable characteristics for bone replacement, including good mechanical properties, excellent corrosion resistance and high biocompatibility. However, one of their main limitations is the fibrous tissue capsule that is formed around the material, which can be related with implants loosening. As an alternative to solve this problem, in this work were carried out some chemical and electrochemical modifications of titanium surface, in order to evaluate their influence on implants osteointegration through in vitro testing in contact with osteoblasts. Results of scanning electron microscopy (SEM), roughness parameters measured and osteoblasts morphology indicate that there is a relationship between surface roughness and bone cells adhesion. Surfaces with highest vertical roughness parameters, within evaluated conditions, allowed better cells adhesion. These results suggest that a combination of chemical and electrochemical techniques can help to control surface roughness of titanium dental implants and, by this way, it can also allow to optimize osteointegration.spa
dc.format.extent12spa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.publisherUniversidad de Antioquia, Facultad de Ingenieríaspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsAtribución-NoComercial-CompartirIgual 2.5 Colombia (CC BY-NC-SA 2.5 CO)*
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/2.5/co/*
dc.subjectEnsayos biológicos-
dc.subjectTitanio-
dc.subjectPropiedades electroquímicas-
dc.subjectImplantes dentales-
dc.titleProcesamiento, caracterización y ensayos biológicos de titanio modificado electroquímicamente para implantes dentalesspa
dc.title.alternativeProcessing, characterization and biological testing of electrochemically modified titanium for dental implantsspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGrupo de Biomateriales Avanzados y Medicina Regenerativa (BAMR)spa
dc.publisher.groupGrupo de Investigación en Biomaterialesspa
dc.publisher.groupGrupo de Investigación en Patología Oral, Periodoncia y Cirugía Alvéolo-Dentaria (POPCAD)spa
dc.publisher.groupPrograma de Estudio y Control de Enfermedades Tropicales (PECET)spa
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn2422-2844-
oaire.citationtitleRevista Facultad de Ingeniería Universidad de Antioquiaspa
oaire.citationstartpage96spa
oaire.citationendpage108spa
oaire.citationissue69spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-sa/4.0/spa
dc.publisher.placeMedellín, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.identifier.urlhttps://revistas.udea.edu.co/index.php/ingenieria/article/view/18305spa
dc.description.researchgroupidCOL0144399spa
dc.description.researchgroupidCOL0055049spa
dc.description.researchgroupidCOL0010074spa
dc.description.researchgroupidCOL0015099spa
dc.relation.ispartofjournalabbrevRev. Fac. Ing. Univ. Antioquiaspa
Aparece en las colecciones: Artículos de Revista en Ingeniería

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
AriasSandra_2013_ProcesamientoCaracterizacionEnsayos.pdfArtículo de investigación1.83 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons