Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/7579
Título : Effect of an electrolyte flow on electrochemical hydrogen permeation
Otros títulos : Efecto de un flujo de electrolito en la permeación electroquímica de hidrógeno
Autor : Pérez Ceballos, Ana María
Calderón Gutiérrez, Jorge Andrés
Rosa Mattos, Oscar
metadata.dc.subject.*: Electrolitos
Hierro
Permeabilidad
Hidrógeno
Sodio
Fecha de publicación : 2014
Editorial : Universidad Nacional de Colombia, Facultad de Minas, Centro de Publicaciones
Citación : Pérez Ceballos, A. M., Calderón Gutiérrez, J. A., & Rosa Mattos, O. (2014). Effect of an electrolyte flow on electrochemical hydrogen permeation. DYNA. 81(187), 152-157. DOI: 10.15446/dyna.v81n186.40960
Resumen : RESUMEN: Se ha estudiado el efecto de la aplicación de un flujo de electrolito sobre la superficie de detección de una membrana de hierro puro en ensayos de permeación electroquímica de hidrógeno. Para la realización de los ensayos se usó una celda del tipo Devanathan modificada, de tal manera que un flujo de electrolito fue inyectado directamente sobre la superficie de salida de hidrógeno. La generación de hidrógeno se realizó aplicando una corriente catódica de 2,85mA y se usó una solución de NaOH 0,1M + 2mgL-1 As2O3. La celda de detección fue mantenida bajo control potenciostático y se usó una solución buffer de borato de sodio (pH=8,4). No se observó una variación significativa de la corriente de permeación en los ensayos realizados aplicando flujo de electrolito.
ABSTARCT: The influence of an electrolyte flux injection over the detection side on pure iron membranes on electrochemical hydrogen permeation test was studied. A modified Devanathan´s cell was used in the experiments. This cell allows the injection of an electrolyte flux over the hydrogen exit side during the permeation tests. In the hydrogen generation compartment a NaOH 0.1M + 2mgL-1 As2O3 solution was used applying a constant current of 2.85 mA. The detection side was maintained under potentiostatic control at potential values in the passivity range for iron. The solution used in the exit compartment was a borate buffer (pH=8.4). It was not observed a significant variation of the permeation current when an electrolyte flow was injected on iron samples, however, a slightly raise both of the steady state of permeation current density and the calculated permeation parameters was observed in the tests in which an electrolyte flux was applied.
metadata.dc.identifier.eissn: 2346-2183
ISSN : 0012-7353
metadata.dc.identifier.doi: 10.15446/dyna.v81n186.40960
Aparece en las colecciones: Artículos de Revista en Ingeniería

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
CalderonJorge_2014_HydrogenPermeation.pdfArtículo de investigación533.5 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons