Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/8572
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorVillarraga Ossa, Junes Abdul-
dc.contributor.authorPavón Palacio, Juan José-
dc.date.accessioned2017-10-17T22:46:56Z-
dc.date.available2017-10-17T22:46:56Z-
dc.date.issued2014-
dc.identifier.citationV. Restrepo, J. A. VIllarraga-Ossa and J. J. Pavón-Palacio, "Stress reduction in the residual limb of a transfemoral amputee varying the coefficient of friction," Journal Prosthetics and Orthotics, vol. 26, no. 4, pp. 205-211, 2014.spa
dc.identifier.issn1040-8800-
dc.identifier.urihttp://hdl.handle.net/10495/8572-
dc.description.abstractABSTRACT: A finite element computer model was used to validate the relationship between coefficient of friction (COF) and the shear stresses and pressures obtained at the socket/residual limb interface for four individuals with transfemoral amputation. This model simulated the process of donning the socket and application of loads during the stance phase of gait cycle. The residual limb was modeled as a solid multilayer (skin, fat and muscle) with hyperelastic properties. An experimental design was made to calculate the significance of hairiness, sweating, and texture factors in measuring the COF between polypropylene and skin with the help of a sclerometer; values were obtained from 0.188 to 0.545. It was demonstrated that the surface texture is significant when measuring the COF. On the results of the simulation, a horizontal strip where the greatest stresses and pressures occurred was identified; in this strip, the COF was varied from 0.2 to 0.6 to observe its effect on the distribution of stresses. The average shear decreased up to 25%, whereas the pressures did not vary significantly and the results do not exceed the value of 70 kPa, from which values are potentially harmful to the skin. Key indexing terms: socket-limb residual interface, finite element analysis, dynamic simulation, stress distribution.spa
dc.format.extent6spa
dc.format.mimetypeapplication/pdfspa
dc.language.isoengspa
dc.publisherLippincott, Williams & Wilkinsspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia*
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/*
dc.subjectInterfase residual de la hebra-extremidad-
dc.subjectDistribución de tensiones-
dc.subjectElementos finitos-
dc.subjectSimulación dinámica-
dc.subjectPrótesis-
dc.subjectProsthesis-
dc.subjectBioengineering-
dc.titleStress reduction in the residual limb of a transfemoral amputee varying the coefficient of frictionspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGrupo de Diseño Mecánicospa
dc.identifier.doi10.1097 / JPO.0000000000000044-
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn1534-6331-
oaire.citationtitleJournal of Prosthetics and Orthoticsspa
oaire.citationstartpage205spa
oaire.citationendpage211spa
oaire.citationvolume26spa
oaire.citationissue4spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-nd/4.0/spa
dc.publisher.placeEstados Unidosspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.relation.ispartofjournalabbrevJPOspa
Aparece en las colecciones: Artículos de Revista en Ingeniería

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
RestrepoVanesa_2014_StressReductionResidualLimb.pdfArtículo de investigación7.13 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons