Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/13120
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorRubio Clemente, Ainhoa-
dc.contributor.authorCardona, A-
dc.contributor.authorChica Arrieta, Edwin Lenin-
dc.contributor.authorPeñuela Mesa, Gustavo Antonio-
dc.date.accessioned2020-01-14T03:09:06Z-
dc.date.available2020-01-14T03:09:06Z-
dc.date.issued2017-
dc.identifier.citationA. Rubio Clemente, C. A. Cardona, E. L. Chica Arrieta, and G. A. Peñuela Mesa, “Sensitive spectrophotometric determination of hydrogen peroxide in aqueous samples from advanced oxidation processes: Evaluation of possible interferences,” Afinidad, vol. 74, no. 579, pp. 161-168, 2017.spa
dc.identifier.issn0001-9704-
dc.identifier.urihttp://hdl.handle.net/10495/13120-
dc.description.abstractRESUMEN: La determinación de peróxido de hidrógeno (H2O2) en muestras de agua real se llevó a cabo de una manera sencilla y sensible. Las condiciones óptimas de funcionamiento resultantes de un diseño experimental factorial completo fueron 450 nm, 50 mm y 6 x 10-3 M de longitud de onda de absorción, longitud de trayectoria de la celda de cuarzo y concentración final de la solución de monovanadato de amonio, respectivamente; permitiendo la cuantificación de 2.94x10-3 mM de H2O2. Se validó el método analítico propuesto y se investigó el efecto de la matriz obteniendo un método selectivo. Además, se aplicó el método analítico desarrollado para estudiar la evolución de H2O2 en la descontaminación de agua que contenía 6,73x10-5 mM de antraceno y 1,19x10-5 mM de benzo[a]pireno utilizando el sistema UV/H2O2. Se encontró que el nivel óptimo de H2O2 que permitía cerca del 45% de mineralización y una eliminación de los hidrocarburos aromáticos policíclicos objeto de estudio superior al 99% fue de 2,94x10-1 mM, permaneciendo aproximadamente 1,47x10-1 mM de H2O2 después de 90 min de tratamiento.spa
dc.description.abstractABSTRACT: Hydrogen peroxide (H2O2) determination in real water samples was carried out in a simple and sensitive way. The resulting optimal operating conditions from a 23 full factorial experimental design were 450 nm, 50 mm and 6x10-3 M for the absorption wavelength, the quartz cell path length and the final concentration of the ammonium monovanadate solution, respectively; allowing the quantification of H2O2 up to 2.94x10-3 mM. The proposed analytical method was validated and the effect of the background matrix was investigated, obtaining a selective method. Additionally, the developed analytical method was applied for studying the evolution of H2O2 in the decontamination of water containing 6.73x10-5 mM of anthracene and 1.19x10-5 mM of benzo[a]pyrene using the UV/H2O2 system. It was found that the optimal H2O2 level enabling about 45% of mineralisation and a removal of the target polycyclic aromatic hydrocarbons higher than 99% was 2.94x10-1 mM, remaining approximately 1.47x10-1 mM of H2O2 after 90 min of treatment.spa
dc.format.extent7spa
dc.format.mimetypeapplication/pdfspa
dc.language.isoengspa
dc.publisherAsociación de Químicosspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia*
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/*
dc.subjectAdvanced oxidation process-
dc.subjectAmmonium monovanadate-
dc.subjectMatrix background-
dc.subjectResidual hydrogen peroxide-
dc.subjectSpectrophotometry-
dc.subjectEspectrofotometría-
dc.titleSensitive spectrophotometric determination of hydrogen peroxide in aqueous samples from advanced oxidation processes : evaluation of possible interferencesspa
dc.title.alternativeDeterminación espectrofotométrica sensible del peróxido de hidrógeno en muestras de agua procedentes de procesos de oxidación avanzada : Evaluación de posibles interferenciasspa
dc.typeinfo:eu-repo/semantics/articlespa
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn2339-9686-
oaire.citationtitleAfinidadspa
oaire.citationstartpage161spa
oaire.citationendpage168spa
oaire.citationvolume74spa
oaire.citationissue579spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-nd/4.0/spa
dc.publisher.placeEspañaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.description.researchgroupidCOL0040402spa
dc.description.researchgroupidCOL0008058spa
Aparece en las colecciones: Artículos de Revista en Ingeniería

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
PenuelaGustavo_2017_SensitiveSpectrophotometric.pdfArtículo de investigación671.37 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons