Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/10495/13357
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Mejía Giraldo, Diego | - |
dc.contributor.author | Muñoz Galeano, Nicolás | - |
dc.date.accessioned | 2020-01-18T03:19:44Z | - |
dc.date.available | 2020-01-18T03:19:44Z | - |
dc.date.issued | 2017 | - |
dc.identifier.citation | A. Castillo-Ramírez, D. Mejía-Giraldo and N. Muñoz-Galeano, “Large-scale solar PV Lcoe comprehensive breakdown methodology,” CT&F - Ciencia, Tecnología y Futuro, vol. 7, no. 1, 117-136. 2017. | spa |
dc.identifier.issn | 0122-5383 | - |
dc.identifier.uri | http://hdl.handle.net/10495/13357 | - |
dc.description.abstract | RESUMEN: Este artículo presenta una metodología para evaluar los costos nivelados de la electricidad (Levelized Cost of Electricity) LCOE , en plantas fotovoltaicas (Photovoltaic - PV) a gran escala. Para ello se propone una desagregación detallada de los LCOE a partir de una taxonomía rigurosa que evalúa los Costos de Inversión (Investment Cost - IC )y los Gastos de Operación (Operation and Maintenance – O&M). Partiendo de la estructura de la Administración de Información Energética (Energy Information Administration – EIA) que desglosa los IC en cinco componentes, hemos añadido un nivel adicional de desagregación denominado elementos. Asimismo, una nueva estructura para desagregar los costos de O&M es presentada. La metodología es evaluada en plantas PV de 20 MW y 150 MW PV hipotéticamente ubicadas en el municipio de Uribia (Guajira Colombia). También se desarrolla un análisis de sensibilidad determinístico usando factores como el Costo Promedio Ponderado de Capital (WACC – Weighted Average Capital Cost), la energía producida, los gastos de O&M y los IC con el ánimo de facilitar las decisiones de los inversionistas. | spa |
dc.description.abstract | ABSTRACT: This paper presents a breakdown cost methodology to evaluate Levelized Costs of Electricity for large-scale Photovoltaic (PV) plants. The breakdown is based on a comprehensive taxonomy to evaluate Investment Costs (IC) and Operation and Maintenance (O&M) expenditures. We added an IC disaggregation level, called elements, on top of the five-component breakdown of the Energy Information Administration (EIA). In addition, a novel structure for disaggregating O&M costs is also proposed. The methodology is evaluated over a 20-MW and a 150-MW PV power plant hypothetically placed in the municipality of Uribia (Guajira Colombia). Also deterministic sensitivity analysis based on discount rate (WACC, Weighted Average Capital Cost), energy generated, O&M costs and IC is performed to aid investors in their decision. | spa |
dc.format.extent | 19 | spa |
dc.format.mimetype | application/pdf | spa |
dc.language.iso | eng | spa |
dc.publisher | ECOPETROL - Instituto Colombiano del Petróleo | spa |
dc.type.hasversion | info:eu-repo/semantics/publishedVersion | spa |
dc.rights | Atribución-NoComercial-CompartirIgual 2.5 Colombia (CC BY-NC-SA 2.5 CO) | * |
dc.rights | info:eu-repo/semantics/openAccess | spa |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/2.5/co/ | * |
dc.subject | Incentives | - |
dc.subject | Investment Costs | - |
dc.subject | Large-Scale Photovoltaic | - |
dc.subject | LCOE breakdown | - |
dc.subject | Operational and Maintenance Costs | - |
dc.subject | WACC | - |
dc.title | Large-scale solar PV Lcoe comprehensive breakdown methodology | spa |
dc.title.alternative | Metodología para la desagregación detallada del Lcoe de plantas fotovoltaicas a gran escala | spa |
dc.type | info:eu-repo/semantics/article | spa |
dc.publisher.group | Grupo de Manejo Eficiente de la Energía (GIMEL) | spa |
oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | spa |
dc.rights.accessrights | http://purl.org/coar/access_right/c_abf2 | spa |
dc.identifier.eissn | 2382-4581 | - |
oaire.citationtitle | CT&F - Ciencia, Tecnología y Futuro | spa |
oaire.citationstartpage | 117 | spa |
oaire.citationendpage | 136 | spa |
oaire.citationvolume | 7 | spa |
oaire.citationissue | 1 | spa |
dc.rights.creativecommons | https://creativecommons.org/licenses/by-nc-sa/4.0/ | spa |
dc.publisher.place | Santander, Colombia | spa |
dc.type.coar | http://purl.org/coar/resource_type/c_2df8fbb1 | spa |
dc.type.redcol | https://purl.org/redcol/resource_type/ART | spa |
dc.type.local | Artículo de investigación | spa |
dc.relation.ispartofjournalabbrev | CT&F | spa |
Aparece en las colecciones: | Artículos de Revista en Ingeniería |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
MunozNicolas_2017_Large-ScaleSolar.pdf | Artículo de investigación | 922.64 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons