Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/20306
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorCaldas Zárate, Rafael-
dc.contributor.authorValbuena Ruiz, Luis Hernando-
dc.contributor.authorJaramillo Londoño, Hilda Νorha-
dc.date.accessioned2021-06-24T00:49:01Z-
dc.date.available2021-06-24T00:49:01Z-
dc.date.issued1998-
dc.identifier.issn0120-2448-
dc.identifier.urihttp://hdl.handle.net/10495/20306-
dc.description.abstractRESUMEN: Objetivos: establecer el perfil característico del V02max, de la PWCmax, de la PWC170 y del IEA para algunas poblaciones deportivas, de sexo femenino y alto rendimiento, del Departamento de Antioquia, Colombia. Método: el estudio se realizó en 221 mujeres competidoras de atletismo de fondo, judo, baloncesto, triatlón, natación, nado sincronizado y patinaje de carrera. La valoración funcional se efectuó con un sistema espirométrico de circuito abierto y de acuerdo con las características y con el gasto motor del deporte evaluado, con un cicloergómetro de frenado electromagnético o con una banda rodante motorizada. Resultados: se presentan los datos del consumo máximo de oxígeno (VO2max), capacidad física máxima de trabajo (PWCmax), capacidad física submáxima de trabajo a 170 pulsaciones por minuto (PWC170), Índice de eficiencia aeróbica (IEA), obtenido de la relación PWC170/WCmax. De acuerdo con los resultados del presente estudio, en mujeres, al contrario de lo encontrado en hombres, las determinaciones del V02max, de la PWCmax y de la PWC170, efectuadas tanto en banda rodante como en cicloergómetro son excelentes indicadores de la capacidad aeróbica. Conclusiones: la presente investigación establece, para la población estudiada, los perfiles ergoespirométricos de algunas variables fisiológicas, con miras a que sirvan como valores de referencia para la selección y la preparación de los diferentes grupos deportivos de alta competencia. Se describe por primera vez las características funcionales, en mujeres, del patinaje de carreras.spa
dc.description.abstractABSTRACT: Objectives: to establish the characteristic profile for Maximal Oxygen Consumption (V02max), Maximal Physical Work Capacity (PWCmax), Physical Work Capacity at 170 bpm (PWC170) and Index of Aerobic Efficiency (IAE) for female top level athletes from the Department of Antioquia (Colombia). Methods: in this study 221 females were evaluated by using an ergospyrometrical open circuit system (Ergo-Oxyscreen Jaeger) in long distance runners, triathlon runners, basketball players, and judo by running on motorized treadmill (Quinton treadmill 1845) according to the Kindermann protocol; on the other hand, swimmers, synchronized swimmers and wrestlers, were evaluated by cycling on a electrodynamic braked cycle (Jaeger), according to the Hollmann protocol. Results: the data of VO,max, PWCmax, PWC170 and IAE for a top level athletes group from the Department of Antioquia (Colombia) are presented. According to our study, both ergometer tests, on treadmill and cycle, are better for to determine VO2max, PWCmax and PWC170* Conclusion: the present investigation establishes for the study population the ergospyrometric profiles of some physiological variable. As reference values they will be helpful in the process of selection and preparation of different top level athletes. The functional characteristic of roller skaters, in women are described for the first time.spa
dc.format.extent5spa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.publisherAsociación Colombiana de Medicina Internaspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by/2.5/co/*
dc.titlePerfil funcional de mujeres deportistas de alto rendimientospa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGrupo de Investigación en Fisiología y Bioquímica - Physisspa
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn2248-6054-
oaire.citationtitleActa Médica Colombianaspa
oaire.citationstartpage151spa
oaire.citationendpage155spa
oaire.citationvolume23spa
oaire.citationissue4spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by/4.0/spa
dc.publisher.placeBogotá, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.subject.decsRendimiento Atlético-
dc.subject.decsAthletic Performance-
dc.subject.lembMujeres deportistas-
dc.subject.lembWomen athletes-
dc.subject.lembPrueba de esfuerzo-
dc.subject.lembTreadmill exercise tests-
dc.identifier.urlhttp://www.actamedicacolombiana.com/anexo/articulos/04-1998-03-.pdfspa
dc.description.researchgroupidCOL0007328spa
dc.relation.ispartofjournalabbrevActa Med Colombspa
Aparece en las colecciones: Artículos de Revista en Ciencias Médicas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
CaldasRafael_1998_PerfilFuncionalMujeres.pdfArtículo de investigación2.45 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons