Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/20309
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorCaldas Zárate, Rafael-
dc.contributor.authorValbuena Ruiz, Luis Hernando-
dc.contributor.authorOrtiz Uribe, Álvaro-
dc.contributor.authorJaramillo Londoño, Hilda Norha-
dc.date.accessioned2021-06-24T01:13:10Z-
dc.date.available2021-06-24T01:13:10Z-
dc.date.issued1996-
dc.identifier.issn0120-2448-
dc.identifier.issn2248-6054-
dc.identifier.urihttp://hdl.handle.net/10495/20309-
dc.description.abstractRESUMEN: Se presentan los datos del consumo máximo de oxígeno (VO2max), de la capacidad física máxima de trabajo (PWCmax) y de la capacidad física máxima de trabajo a 170 pulsaciones por minuto (PWC170), de un grupo de deportistas de alto rendimiento, oriundos del departamento de Antioquia (Colombia). El estudio se realizó en 857 hombres competidores de atletismo de fondo, lucha olímpica, baloncesto, fútbol, microfútbol, ciclismo de pista, natación, patinaje y polo acuático. La valoración funcional se efectuó con un sistema espirométrico de circuito abierto y con un cicloergómetro de frenado electromagnético o una banda rodante motorizada, de acuerdo con las características y el gesto motor del deporte evaluado. De acuerdo con los resultados del presente estudio, en los deportes pedestres evaluados con la banda rodante, las determinaciones del VO2max, de la PWCmax y de la PWC170, son excelentes indicadores de la capacidad aeróbica, pero no lo son cuando para su determinación se emplea el cicloergómetro; quizás esto se deba a que la ejecución del trabajo en el cicloergómetro compromete masas musculares y gestos motores diferentes a los empleados comúnmente. Se propone la relación PWC]70/PWCmax como un indicador de la eficiencia en la utilización de la capacidad aeróbica, útil para el diseño y control de los planes de entrenamiento en aquellos deportes en los cuales los procesos aeróbicos son determinantes para un adecuado desempeño.spa
dc.description.abstractABSTRACT: Maximum Oxygen Consumption (max V02 ), Maximum Physical Work Capacity (max PWC) and Physical Work Capacity at 170 beats per minute (PWC170) were determined in 857 top level male athletes from Antioquia (Colombia), by using an ergoespyrometrical open circuit system (Ergooxiscreen Jaeger) at laboratory conditions (1560 meters above sea level, 25°C and 65% relative humidity). By running on motorized treadmill (Quinton treadmill 1.845) according to the protocol described by Kindermann et al (1980) long distance runners; triathletes; basketball, soccer and indoor players; and wrestlers were evaluated. By cycling on an electrodynamic braked cycle (Jaeger) swimmers, rollerskaters, track cyclists and water polo players were evaluated. The treadmill test is a good ergometer to determine VO2max, PWCmax and PWC170, meanwhile the cycle ergometer has shown low specificity for these parameters specially in water sports. The long distance runners have shown the best result in VO2max, PWCmax and PWC170 . On the other hand, swimmers have shown the worst result for all the parameters apparently originated in the low specificity of the ergometer. By comparing with other studies, a similar level of aerobic performance and PWC was found.spa
dc.format.extent6spa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.publisherAsociación Colombiana de Medicina Internaspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by/2.5/co/*
dc.titleCaracterísticas funcionales de deportistas antioqueños de alto rendimientospa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGrupo de Investigación en Fisiología y Bioquímica - Physisspa
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
oaire.citationtitleActa Médica Colombianaspa
oaire.citationstartpage162spa
oaire.citationendpage167spa
oaire.citationvolume21spa
oaire.citationissue4spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by/4.0/spa
dc.publisher.placeBogotá, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.subject.decsEjercicio Físico-
dc.subject.decsExercise-
dc.subject.decsConsumo de Oxígeno-
dc.subject.decsOxygen Consumption-
dc.subject.lembAptitudes físicas - pruebas-
dc.subject.lembPhysical fitness - testing-
dc.subject.lembDeportistas-
dc.subject.lembAthletes-
dc.identifier.urlhttp://www.actamedicacolombiana.com/anexo/articulos/04-1996-05-Caracteristicas_funcionales_de_deportistas_antioq.pdfspa
dc.description.researchgroupidCOL0007328spa
dc.relation.ispartofjournalabbrevActa Med Colombspa
Aparece en las colecciones: Artículos de Revista en Ciencias Médicas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
CaldasRafael_1996_CaracteristicasDeportistasAntioquenos.pdfArtículo de investigación14.3 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons