Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/23005
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorFernández Cadavid, Andrés-
dc.contributor.authorRodríguez Di Muro, Arturo-
dc.contributor.authorSénior Sánchez, Juan Manuel-
dc.contributor.authorAldana, Víctor-
dc.contributor.authorBorja Romero, Henry Miguel-
dc.date.accessioned2021-10-07T22:37:59Z-
dc.date.available2021-10-07T22:37:59Z-
dc.date.issued2017-
dc.identifier.issn0120-5633-
dc.identifier.urihttp://hdl.handle.net/10495/23005-
dc.description.abstractRESUMEN: Objetivo: Evaluar la seguridad y eficacia del cierre percutáneo de la orejuela izquierda en pacientes con fibrilación auricular no valvular con alto riesgo de sangrado o con contraindicación para anticoagulación oral. Métodos: Estudio prospectivo no aleatorizado en una cohorte de pacientes con fibrilación auricular con contraindicación o dificultades con anticoagulación oral y puntaje de CHA2DS2-VASc ≥ 2 y de HASBLED ≥ 2, elegibles para doble antiagregación con aspirina y clopidogrel. Resultados: Se incluyeron 53 pacientes, con edad promedio de 72,24 ± 9,22 anos, ̃ de los cuales 54,72% eran hombres; 20,75% tenían fibrilación auricular paroxística, 15,1% persistente y 64,15% permanente. Además, 18,9% tenían insuficiencia cardíaca, 22,64% enfermedad coronaria, 92,45% hipertensión arterial, 41,51% eran mayores de 75 anos, ̃ 18,9% eran diabéticos y 37,7% tenían enfermedad cerebrovascular previa. El promedio del puntaje de CHADS2 y CHA2DS2-VASc fue de 2,73 ± 1,34 y 4,24 ± 1,54, respectivamente. El procedimiento fue exitoso en un 98% (52/53). Sólo en un caso no fue posible implantar el dispositivo por causas anatómicas. No hubo eventos adversos serios relacionados con la implantación; durante el procedimiento se registró un episodio de derrame pericárdico leve que no requirió drenaje. En los 45 días de seguimiento, 2 pacientes (3,77%) desarrollaron enfermedad cerebrovascular y se registró un deceso por causa no cardíaca (1,89%). Conclusiones: El cierre percutáneo de la orejuela izquierda con dispositivo WATCHMAN® es un procedimiento seguro y eficaz en pacientes de alto riesgo con fibrilación auricular no valvular y contraindicación o dificultades para la anticoagulación oral.spa
dc.description.abstractABSTRACT: Motivation: To assess the safety and efficacy of percutaneous left atrial appendage closure in patients with non-valvular atrial fibrillation with a high risk of bleeding or a contraindication to oral anticoagulation drugs. Methods: Prospective non-randomised study of a cohort of patients with atrial fibrillation who had a contraindication to or difficulties with oral anticoagulation, CHA2DS2-VASc ≥ 2 and HAS- BLED ≥ 2 scores, and who were eligible for dual antiaggregation therapy with aspirin and clopidogrel. Results: 53 patients with an average age of 72.24 ± 9.22 years were included, out of whom 54.72% were men, 20.75% had paroxysmal, 15.1% persistent and 64.15% permanent atrial fibrillation, respectively. Besides, 18.9% suffered from heart failure, 22.64% from coronary disease, 92.45% from arterial hypertension, 41.51% were over 75 years old, 18.9% were diabetic and 37.7% had a history of cerebrovascular disease. Average CHADS2 y CHA2DS2-VASc scores were of 2.73 ± 1.34 and 4.24 ± 1.54 respectively. Procedure was successful in 98% of the cases (52/53). It was not possible to implant the device in only one case due to anatomical reasons. There were no severe adverse events related to the insertion; during the procedure an episode of mild pericardial effusion that did not require drainage was registered. DUring the 45-day follow up period, 2 patients (3.77%) developed a cerebrovascular disease, and there was one noncardiac death (1.89%). Conclusions: The percutaneous left atrial appendage closure with device is a safe and efficient procedure in high-risk patients with non-valvular atrial fibrillation and contraindications to or difficulties for oral anticoagulation therapy.spa
dc.format.extent7spa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.publisherSociedad Colombiana de Cardiología y Cirugía Cardiovascularspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/*
dc.titleSeguridad y eficacia a corto plazo del cierre de orejuela izquierda con dispositivo WATCHMAN® en fibrilación auricular no valvular en pacientes con alto riesgo de sangradospa
dc.title.alternativeShort-term safety and efficacy of left atrial appendage closure using WATCHMAN® device for non-valvular atrial fibrillation in patients with a high risk of bleedingspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGrupo para el Estudio de las Enfermedades Cardiovascularesspa
dc.identifier.doi10.1016/j.rccar.2016.10.048-
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn2357-3260-
oaire.citationtitleRevista Colombiana de Cardiologíaspa
oaire.citationstartpage369spa
oaire.citationendpage375spa
oaire.citationvolume24spa
oaire.citationissue4spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-nd/4.0/spa
dc.publisher.placeBogotá, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.subject.decsFibrilación Atrial-
dc.subject.decsAtrial Fibrillation-
dc.subject.lembApoplejía-
dc.subject.lembCerebrovascular disease-
dc.description.researchgroupidCOL0135865spa
dc.relation.ispartofjournalabbrevRev. Colomb. Cardiol.spa
Aparece en las colecciones: Artículos de Revista en Ciencias Médicas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
SeniorJuan_2017_DispositivoWatchmanFibrilacion.pdfArtículo de investigación320.13 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons