Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/26591
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorFandiño Devia, Estefanía-
dc.contributor.authorRodríguez Echeverri, Carolina-
dc.contributor.authorCardona Arias, Jaiberth Antonio-
dc.contributor.authorGonzález Marín, Ángel Augusto-
dc.date.accessioned2022-03-14T20:03:05Z-
dc.date.available2022-03-14T20:03:05Z-
dc.date.issued2016-
dc.identifier.citationFandiño-Devia E, Rodríguez-Echeverri C, Cardona-Arias J, Gonzalez A. Antigen Detection in the Diagnosis of Histoplasmosis: A Meta-analysis of Diagnostic Performance. Mycopathologia. 2016 Apr;181(3-4):197-205. doi: 10.1007/s11046-015-9965-3.spa
dc.identifier.issn0301-486X-
dc.identifier.urihttp://hdl.handle.net/10495/26591-
dc.description.abstractABSTRACT : We performed a meta-analysis of diagnostic data to evaluate the performance of Histoplasma antigen detection tests for diagnosing histoplasmosis. We included all studies involving human subjects that assessed the performance of any antigen detection test for histoplasmosis in urine or serum by carrying out an exhaustive and reproducible search of the literature between 1980 and 2014 from four databases. Quality of the articles was assessed, and meta-analysis was performed under the random effects model, calculating sensitivity, specificity, likelihood and odds ratios, and ROC curve using Meta-DiSc(es). Nine out of a total of 23 studies met strict quality criteria and were therefore included. The overall sensitivity for antigen detection in serum and urine was 81 % (95 % CI 78–83 %), while specificity was 99 % (95 % CI 98–99 %). Sensitivity for antigenuria and antigenemia was 79 % (95 % CI 76–82 %) and 82 % (95 % CI 79–85 %), respectively; specificity values were 99 % (95 % CI 98–100 %) in urine and 97 % (95 % CI 96–98 %) in serum. The positive and negative likelihood ratios were 49.5 (95 % CI 20.7–118.7) and 0.19 (95 % CI 0.14–0.26), respectively, while the diagnostic OR was 362 (95 % CI 121.2–1080.3) and area under the curve was 0.99. In conclusion, the performance of Histoplasma antigen detection assay of urine was not significantly different from that of blood, indicating that antigenuria and antigenemia have equal diagnostic value in histoplasmosis.spa
dc.format.extent9spa
dc.format.mimetypeapplication/pdfspa
dc.language.isoengspa
dc.publisherSpringerspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by/2.5/co/*
dc.titleAntigen Detection in the Diagnosis of Histoplasmosis : A Meta-analysis of Diagnostic Performancespa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGrupo de Investigación en Microbiología Básica y Aplicada-Microbaspa
dc.identifier.doi10.1007/s11046-015-9965-3-
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn1573-0832-
oaire.citationtitleMycopathologiaspa
oaire.citationstartpage197spa
oaire.citationendpage205spa
oaire.citationvolume181spa
oaire.citationissue3-4spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by/4.0/spa
dc.publisher.placeLa Haya, Países Bajosspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.subject.decsHistoplasmosis-
dc.subject.decsDiagnóstico-
dc.subject.decsDiagnosis-
dc.subject.decsAntígenos Fúngicos-
dc.subject.decsAntigens, Fungal-
dc.subject.decsEnsayo de Inmunoadsorción Enzimática-
dc.subject.decsEnzyme-Linked Immunosorbent Assay-
dc.subject.decsEnfermedades Pulmonares-
dc.subject.decsLung Diseases-
dc.subject.decsSensibilidad y Especificidad-
dc.subject.decsSensitivity and Specificity-
dc.subject.decsRadioinmunoensayo-
dc.subject.decsRadioimmunoassay-
dc.description.researchgroupidCOL0126131spa
dc.description.researchgroupidCOL0088881spa
dc.relation.ispartofjournalabbrevMycopathologiaspa
Aparece en las colecciones: Artículos de Revista en Microbiología

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
FandiñoEstefanía_2016_AntigenDetectionInTheDiagnosis.pdfArtículo de investigación1.14 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons