Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/33886
Título : Metaanálisis de la validez diagnóstica de las pruebas de tamización del virus de inmunodeficiencia humana en bancos de sangre, 2000-2020
Otros títulos : Meta-analysis of the diagnostic validity of human immunodeficiency virus screening tests in blood banks, 2000-2020
Meta-análise da validade diagnóstica dos testes de triagem do vírus da imunodeficiência humana em bancos de sangue, 2000-2020
Autor : Cardona Arias, Jaiberth Antonio
Orrego Marín, Claudia Patricia
metadata.dc.subject.*: Reproducibilidad de los Resultados
Reproducibility of Results
Bancos de Sangre
Blood Banks
Metaanálisis
Meta-Analysis
VIH
HIV
Ensayo de Inmunoadsorción Enzimática
Enzyme-Linked Immunosorbent Assay
Fecha de publicación : 2022
Editorial : Universidad de Antioquia, Facultad Nacional de Salud Pública
Citación : Cardona-Arias JA, Orrego-Marín CP. Metaanálisis de la validez diagnóstica de las pruebas de tamización del virus de inmunodeficiencia humana en bancos de sangre, 2000-2020. Rev. Fac. Nac. Salud Pública. 2022;40(3):e347170. doi: https://doi. org/10.17533/udea.rfnsp.e347170
Resumen : RESUMEN: Objetivo: Evaluar la validez diagnóstica del ensayo de inmunoabsorción ligado a enzima (Enzyme-Linked Immunosorbent Assay, elisa) para el virus de inmunodeficiencia humana (vih) en bancos de sangre, con base en estudios publicados entre 2000 y 2020. Metodología: Se realizó una revisión sistemática y metaanálisis de pruebas diagnósticas, mediante un modelo de efectos aleatorios para la sensibilidad, la especificidad, el cociente de probabilidad positivo y negativo, la razón de odds (or) diagnóstica y la curva roc, con sus intervalos de confianza del 95 %. La heterogeneidad se evaluó con el estadístico Q(χ2) DerSimonian-Laird y el I2 de inconsistencia, y la incertidumbre, con el porcentaje de peso de cada estudio. Resultados: Se incluyeron 15 investigaciones; la elisa de tercera generación (detección de anticuerpos) se aplicó en 2992 infectados y 4076 sanos; las de cuarta generación (determinación simultánea de antígeno-anticuerpo), en 967 infectados y 154 264 sanos; ambas presentaron sensibilidad cercana al 100 %, pero la especificidad fue mejor en los ensayos de cuarta generación (98 vs. 100 %). Para ambas tecnologías, los cocientes de probabilidad, or diagnóstica y curva roc evidenciaron excelente discriminación de sanos e infectados. Conclusión: Se confirmó que las elisa de tercera y cuarta generación presentan excelente validez y utilidad diagnóstica en donantes de sangre, lo que es importante para las políticas de sangre segura y control del vih.
ABSTRACT: Objective: To evaluate the diagnostic validity of the enzyme-linked immunosorbent assay (ELISA) for human immunodeficiency virus (HIV) in blood banks, based on studies published between 2000 and 2020. Methodology: We performed a systematic review and meta-analysis of diagnostic tests, using a random-effects model for the sensitivity, specificity, positive and negative likelihood ratio, diagnostic odds ratio (DOR), and ROC curve, with 95% confidence intervals. Heterogeneity was assessed with the DerSimonian- Laird Q(χ2) statistic and the I2 inconsistency statistic. Uncertainty was assessed using percentage study weights. Results: 15 studies were included. The third-generation ELISA (antibody detection) was applied for 2,992 infected and 4,076 healthy individuals, and the fourth-generation ELISA (simultaneous antigen-antibody detection) was used for 967 infected and 154,264 healthy individuals. Both showed close to 100% sensitivity, but there was an improved specificity in the fourth-generation assays (98% vs. 100%). Both technologies’ likelihood ratios, DOR, and ROC curve aptly distinguished between healthy and infected individuals. Conclusion: The third and fourth-generation ELISA were confirmed to have excellent validity and diagnostic utility in blood donors, which is important for HIV control and blood safety policies.
RESUMO: Objetivo: Avaliar a validade diagnóstica do ensaio de imunoabsorção ligado à enzima (Enzyme-Linked Immunosorbent Assay, ELISA) para o vírus de imunodeficiência humana (VIH) em bancos de sangue, com base em estudos publicados entre 2000 e 2020. Metodologia: Realizou-se uma revisão sistemática e meta-análise de provas diagnósticas, por meio de um modelo de efeitos aleatórios para a sensibilidade, a especificidade, o cociente de probabilidade positivo e negativo, a razão de odds (OR) diagnóstica e a curva de ROC, com seus intervalos de confiança do 95%. A heterogeneidade foi avaliada com o estatístico Q(χ2) DerSimonian-Laird e o I2 de inconsistência, e a incerteza, com a porcentagem de peso de cada estudo. Resultados: Foram incluídas 15 pesquisas; a ELISA de terceira geração (detecção de anticorpos) aplicouse em 2992 infetados e 4076 sadios; as de quarta geração (determinação simultânea de antígeno-anticorpos), em 967 infetados e sadios; ambas as duas apresentaram sensibilidade próxima ao 100%, mas a especificidade foi melhor nos ensaios de quarta geração (98 vs. 100%). Para ambas as tecnologias, os cocientes de probabilidade, OR diagnóstica e curva ROC evidenciaram excelente discriminação de sadios e infetados. Conclusão: Confirmou-se que as ELISA de terceira e quarta geração apresentam excelente validade e utilidade diagnóstica em doadores de sangue, o que é importante para as políticas de sangue seguro e controle do VIH.
metadata.dc.identifier.eissn: 2256-3334
ISSN : 0120-386X
metadata.dc.identifier.doi: 10.17533/udea.rfnsp.e347170
Aparece en las colecciones: Artículos de Revista en Microbiología

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
CardonaAriasJaiberth_2022_MetaanalisisTamizacionVIH.pdfArtículo de revisión1.78 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons