Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/35248
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorCastaño González, Juan Guillermo-
dc.contributor.authorChico, Belén-
dc.contributor.authorLópez Delgado, Aurora-
dc.contributor.authorMorcillo Linares, Manuel-
dc.contributor.authorLobo Recio, María de los Ángeles-
dc.contributor.authorDe La Fuente, Daniel-
dc.contributor.authorLópez Gómez, Félix Antonio-
dc.date.accessioned2023-06-01T18:47:14Z-
dc.date.available2023-06-01T18:47:14Z-
dc.date.issued2004-
dc.identifier.issn0366-3175-
dc.identifier.urihttps://hdl.handle.net/10495/35248-
dc.description.abstractRESUMEN: Es de sobra conocida la influencia que ejerce la temperatura en la capacidad resistente del acero estructural. Un sistema de protección del acero, altamente efectivo y de uso creciente, consiste en la utilización de pinturas intumescentes, las cuales en el caso eventual de un incendio, retardan la acción destructora del mismo. Su efectividad se basa en el hecho de que al entrar en contacto con la llama reaccionan hinchándose y formando una capa aislante que se denomina intumescencia y que impide la propagación del calor. Aunque en general estas pinturas no precisan de un mantenimiento continuo, su comportamiento en servicio depende de las condiciones de exposición. Este trabajo estudia el comportamiento de un sistema intumescente de tipo caucho acrilado expuesto en dos atmósferas de exterior. Al mismo tiempo se estudia también dicho sistema protegido mediante la aplicación de una capa de acabado posterior. La capacidad de intumescer del recubrimiento ha sido medida antes y después de la exposición a la atmósfera correspondiente, mediante ensayos de resistencia al fuego aplicados a escala de laboratorio. La evolución con el tiempo de exposición del comportamiento del recubrimiento ha sido estudiada mediante análisis térmico (TG/DTA) y espectroscopía infrarroja (FTIR).spa
dc.description.abstractABSTRACT: The influence exerted by temperature on the resistant capacity of structural steel is well known. A highly efficient and increasingly widely used protection system for steel consists of the application of intumescent paints, which in the case of fire retard its destructive action. Their effectiveness is based on the property that when they come into contact with flames they react by swelling to form an insulating layer, referred to as intumescence, which impedes the propagation of heat. Though in general these paints do not require continuous maintenance, their service behaviour depends on the exposure conditions to which they are exposed. This paper studies the behaviour of an acrylated rubber type intumescent system exposed to two outdoor atmospheres. The same system is also studied with the protection of a topcoat paint layer. The coating’s capacity to intumesce has been measured before and after its exposure to the corresponding atmospheres by means of fire resistance tests applied at laboratory scale. The evolution of the coating’s behaviour with exposure time has been studied by means of thermal analysis (TG/DTA) and infrared spectroscopy (FTIR).spa
dc.format.extent4spa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.publisherElsevierspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/*
dc.titleDegradación atmosférica de un recubrimiento de pintura intumescentespa
dc.title.alternativeAtmospheric degradation of an intumescent paint coatingspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupCentro de Investigación Innovación y Desarrollo de Materiales (CIDEMAT)spa
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn2173-0431-
oaire.citationtitleBoletín de la Sociedad Española de Cerámica y Vidriospa
oaire.citationstartpage216spa
oaire.citationendpage219spa
oaire.citationvolume43spa
oaire.citationissue2spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-nd/4.0/spa
dc.publisher.placeMadrid, Españaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.subject.lembAcero-
dc.subject.agrovocSteel-
dc.subject.agrovocResistencia al fuego-
dc.subject.agrovocFire resistance-
dc.subject.proposalIntumescenciaspa
dc.subject.agrovocurihttp://aims.fao.org/aos/agrovoc/c_648efc0d-
dc.description.researchgroupidCOL0007927spa
dc.relation.ispartofjournalabbrevBol. Soc. Esp. Cerám. Vidr.spa
Aparece en las colecciones: Artículos de Revista en Ingeniería

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
CastañoJuan_2004_DegradacionAtmosferica.pdfArtículo de investigación583.49 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons