metadata.dc.subject.*: | Glándula tiroides Thyroid gland Neoplasias de la tiroides Thyroid neoplasms Nódulo tiroideo Thyroid nodule Ultrasonografía Ultrasonography https://id.nlm.nih.gov/mesh/D013961 https://id.nlm.nih.gov/mesh/D013964 https://id.nlm.nih.gov/mesh/D016606 https://id.nlm.nih.gov/mesh/D014463 |
Fecha de publicación : | 2023 |
Resumen : | RESUMEN: Introducción: La ecografía tiroidea es la herramienta más importante en el estudio y estadificación del nódulo tiroideo, no obstante, su utilidad está supeditada a un adecuado reporte que permita su interpretación y análisis. El objetivo de este estudio es evaluar la adherencia de los reportes de ecografías tiroideas de acuerdo con un sistema estandarizado. Métodos: 215 ecografías fueron calificadas de acuerdo con los parámetros de reporte propuestos por el panel de expertos reunidos por la Thyroid, Head and Neck Cancer (THANC) Foundation. Todas las ecografías fueron realizadas en el año 2022, en el Hospital Alma Máter de Antioquia, institución de cuarto nivel de la ciudad de Medellín, Colombia.
Resultados: En los reportes de ecografías tan solo el 44 % de las descripciones de los nódulos tiroideos, el 16 % de las descripciones de la glándula tiroides y ninguna de las descripciones de los ganglios linfáticos completó más o igual al 75 % de los parámetros evaluados. El reporte de algunos elementos esenciales fue de carácter infrecuente como la extensión de la glándula tiroides a mediastino (6 %), el reporte de la relación entre el alto y el ancho (24 %), los contornos (40 %) y la presencia de calcificaciones (43 %) de los nódulos.
Conclusiones: Los resultados del estudio revelan que gran parte de los reportes ecográficos estudiados no cuentan con una calidad adecuada, se debe iniciar de ABSTRACT: Introduction: Thyroid ultrasound is the most important tool in the study and staging of the thyroid nodule, however, its usefulness is conditioned to an adequate report that allows its interpretation and analysis. The aim of this study is to evaluate the adherence of thyroid ultrasound reports according to a standardized system. Methods: 215 ultrasounds were scored according to the reporting parameters proposed by the panel of experts assembled by the Thyroid, Head and Neck Cancer Foundation (THANC). All the ultrasounds were performed in the year 2022, at the Alma Mater Hospital of Antioquia, a fourth level institution in the city of Medellin, Colombia. Results: In the ultrasound reports only 44 % of the descriptions of thyroid nodules, 16 % of the descriptions of the thyroid gland and none of the descriptions of the lymph nodes completed more or equal to 75 % of the evaluated parameters. The report of some essential features was uncommon, such as, the extension of the thyroid gland to mediastinum (6 %), the report of the ratio between height and width (24 %), the contours (40 %) and the presence of calcifications (43 %) of the nodules. Conclusions: The results of the study reveal that a large part of the ultrasound reports do not have an adequate quality, actions to improve and optimize thyroid ultrasound reporting should be initiated as a priority. |