Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/10495/35897
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Zamudio Burbano, Mario Andrés | - |
dc.contributor.author | Giraldo Salazar, Olga | - |
dc.contributor.author | Gaviria Rivera, Elmer de Jesús | - |
dc.contributor.author | Gómez Castellanos, Guillermo | - |
dc.contributor.author | Rodríguez, Cesar Ángel | - |
dc.contributor.author | Medina Ramírez, Santiago | - |
dc.contributor.author | Ramírez Latorre, Juan Luis | - |
dc.contributor.author | Herrera Caviedes, Laura Andrea | - |
dc.date.accessioned | 2023-07-12T18:53:37Z | - |
dc.date.available | 2023-07-12T18:53:37Z | - |
dc.date.issued | 2018 | - |
dc.identifier.citation | Zamudio-Burbano MA, Giraldo-Salazar O, Gaviria-Rivera E, Gómez-Castellanos G, Ángel Rodríguez C, Medina Ramírez S, et al. Intubación traqueal con dispositivo supraglótico I-gel en pacientes pediátricos: Serie de casos prospectiva. Rev Colomb Anestesiol. 2018;46:40–44. | spa |
dc.identifier.issn | 0120-3347 | - |
dc.identifier.uri | https://hdl.handle.net/10495/35897 | - |
dc.description.abstract | RESUMEN: Introducción: No hay un dispositivo en la actualidad que demuestre apropiado porcentaje de éxito de intubación a ciegas en pediatría. Objetivos: El propósito de esta serie de casos es conocer el porcentaje de éxito de intubación a ciegas a través de la máscara laríngea I-gel en niños pesando entre 2 y 35 kilos, además evaluarla presión de sello, la visión fibroscópica a través del dispositivo y reportar la aparición de complicaciones. Materiales y Métodos: Serie prospectiva de casos en pediatría, en pacientes de 2 a 35 kilos. Resultados: En nuestro estudio el porcentaje global de intubación a ciegas fue del 23%, el porcentaje de visión ideal y visión baja, que permiten fácil introducción del broncoscopio en la vía aérea y luego a través del fibroscopio introducir un tubo traqueal, fue de un 70%. Conclusiones: Consideramos que el I-gel supraglótico no es un dispositivo adecuado para intubación a ciegas. Sin embargo, tiene un valor aceptable para recomendar realizar intubación fibro-óptica a través del dispositivo supraglótico I-gel. | spa |
dc.description.abstract | ABSTRACT: Introduction: Currently there are no devices showing anacceptable success rate in blind intubation in pediatrics. Objetive: The purpose of this particular series of cases in toidentify the percentage of successful blind intubations using theI-gel laryngeal mask in children between 2 and 35 kilos of bodyweight, in addition to evaluating seal pressure,fiber opticsvision through the device and reporting the occurrence ofcomplications. Materialsand methods: A prospective case series in pediatrics;patients from 2 to 35 kilos. Results: According to our study, the overall percentage of blindintubation was 23%, while the percentages of ideal and low visionto facilitate the insertion of the bronchoscope into the airway, andthen inserting a tracheal tube through thefiber optics was 70%. Conclusions:We feel that the supraglottic I-gel is not theappropriate device for blind intubation; however, it is anacceptable recommendation to conductfiber optics intubation. | spa |
dc.format.extent | 5 páginas | spa |
dc.format.mimetype | application/pdf | spa |
dc.language.iso | eng | spa |
dc.language.iso | spa | spa |
dc.publisher | Sociedad Colombiana de Anestesiología y Reanimación | spa |
dc.type.hasversion | info:eu-repo/semantics/publishedVersion | spa |
dc.rights | info:eu-repo/semantics/openAccess | spa |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/2.5/co/ | * |
dc.title | Tracheal intubation with I-gel supraglottic device in pediatric patients: a prospective case series | spa |
dc.title.alternative | Intubación traqueal con dispositivo supraglóticoI-gel en pacientes pediátricos: Serie de casosprospectiva | spa |
dc.type | info:eu-repo/semantics/article | spa |
dc.publisher.group | Grupo de Investigación en Medicina Perioperatoria (GRIMPA) | spa |
dc.identifier.doi | 10.1097/CJ9.0000000000000007 | - |
oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | spa |
dc.rights.accessrights | http://purl.org/coar/access_right/c_abf2 | spa |
dc.identifier.eissn | 2422-0248 | - |
oaire.citationtitle | Revista Colombiana de Anestesiología | spa |
oaire.citationstartpage | 37 | spa |
oaire.citationendpage | 41 | spa |
oaire.citationvolume | 46 | spa |
oaire.citationissue | 1 | spa |
dc.rights.creativecommons | https://creativecommons.org/licenses/by-nc-nd/4.0/ | spa |
dc.publisher.place | Bogotá, Colombia | spa |
dc.type.coar | http://purl.org/coar/resource_type/c_2df8fbb1 | spa |
dc.type.redcol | https://purl.org/redcol/resource_type/ART | spa |
dc.type.local | Artículo de investigación | spa |
dc.subject.decs | Intubación Intratraqueal | - |
dc.subject.decs | Intubation, Intratracheal | - |
dc.subject.decs | Manejo de la Vía Aérea | - |
dc.subject.decs | Airway Management | - |
dc.subject.decs | Ventilation | - |
dc.subject.decs | Ventilation | - |
dc.subject.decs | Anestesia | - |
dc.subject.decs | Anesthesia | - |
dc.subject.decs | Pediatría | - |
dc.subject.decs | Pediatrics | - |
dc.subject.decs | Informes de Casos | - |
dc.subject.decs | Case Reports | - |
dc.description.researchgroupid | COL0094314 | spa |
dc.relation.ispartofjournalabbrev | Rev. Colomb. Anestesiol. | spa |
Aparece en las colecciones: | Artículos de Revista en Ciencias Médicas |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
ZamudioAndrés_2018_IntubaciónTraquealPediátricos.pdf | Artículo de investigación | 123.65 kB | Adobe PDF | Visualizar/Abrir |
ZamudioAndrés_2018_TrachealIntubationPediatric.pdf | Artículo de investigación | 200.12 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons