Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/10495/36344
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | López Lezama, Jesús María | - |
dc.contributor.author | Gallego Rendón, Ramón Alfonso | - |
dc.contributor.author | Granada Echeverri, Mauricio | - |
dc.date.accessioned | 2023-08-24T15:06:12Z | - |
dc.date.available | 2023-08-24T15:06:12Z | - |
dc.date.issued | 2014 | - |
dc.identifier.citation | ranada-Echeverri, M.; Gallego-Rendón, R.A.; López Lezema, J.M. (2014). Combined Optimal Tap Setting and Reactive Power Injection for Loss Reduction in Distribution System. Revista EIA, 11(21) enero-junio, pp. 13-21. [Online]. Disponible en: http://dx.doi.org/10.14508/ reia.2014.11.21.13-21 | spa |
dc.identifier.issn | 1794-1237 | - |
dc.identifier.uri | https://hdl.handle.net/10495/36344 | - |
dc.description.abstract | ABSTRACT: This paper presents an optimization model for a combined scheme of optimal tap setting and reactive power injection in distribution systems. The proposed model provides the reactive power injection and tap setting scheme that would minimize losses, keeping voltage magnitudes within specified limits, at minimum cost. The formulation is done as an optimal reactive power flow and is solved using commercial available software. Several tests are performed on a 33-bus distribution test system. The results obtained showed that the combined use of tap setting and reactive power injection leads to higher loss reduction than the use of any of these actions separately. | spa |
dc.description.abstract | RESUMEN: En este artículo se presenta un modelo de optimización para un esquema combinado de movimiento óptimo de taps e inyección óptima de reactivos en sistemas de distribución. El modelo propuesto indica las inyecciones de reactivos y el esquema de posicionamiento taps que minimiza las pérdidas manteniendo las tensiones en los límites permitidos, a mínimo costo. La formulación se realiza mediante un flujo de potencia óptimo reactivo y es solucionado usando un software comercial. Varias pruebas son realizadas en un sistema de distribución de 33 barras. Los resultados muestran que el uso combinado de cambio de taps e inyección de reactivos conducen a una reducción mayor de pérdidas que el uso de estas acciones por separado. | spa |
dc.format.extent | 9 | spa |
dc.format.mimetype | application/pdf | spa |
dc.language.iso | eng | spa |
dc.publisher | Escuela de Ingeniería de Antioquia | spa |
dc.type.hasversion | info:eu-repo/semantics/publishedVersion | spa |
dc.rights | info:eu-repo/semantics/openAccess | spa |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/2.5/co/ | * |
dc.subject.lcsh | Distribución (teoría de la probabilidad) | - |
dc.subject.lcsh | Distribution (Probability theory) | - |
dc.subject.lcsh | http://id.loc.gov/authorities/subjects/sh85038545 | - |
dc.title | Combined optimal tap setting and reactive power injection for loss reduction in distribution systems | spa |
dc.title.alternative | Esquema combinado de movimiento óptimo de taps e inyección de reactivos para reducción de pérdidas en sistemas de distribución | spa |
dc.type | info:eu-repo/semantics/article | spa |
dc.publisher.group | Grupo de Manejo Eficiente de la Energía (GIMEL) | spa |
dc.identifier.doi | 10.14508/reia.2014.11.21.13-21 | - |
oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | spa |
dc.rights.accessrights | http://purl.org/coar/access_right/c_abf2 | spa |
dc.identifier.eissn | 2463-0950 | - |
oaire.citationtitle | Revista EIA | spa |
oaire.citationstartpage | 13 | spa |
oaire.citationendpage | 21 | spa |
oaire.citationvolume | 11 | spa |
oaire.citationissue | 21 | spa |
dc.rights.creativecommons | https://creativecommons.org/licenses/by-nc-nd/4.0/ | spa |
dc.publisher.place | Envigado, Colombia | spa |
dc.type.coar | http://purl.org/coar/resource_type/c_2df8fbb1 | spa |
dc.type.redcol | https://purl.org/redcol/resource_type/ART | spa |
dc.type.local | Artículo de investigación | spa |
dc.subject.lemb | Potencia Reactiva (Ingeniería Electrica) | - |
dc.subject.lemb | Reactive power (electrical engineering) | - |
dc.subject.proposal | Reducción de pérdidas | spa |
dc.subject.proposal | Inyecciones de reactivos | spa |
dc.description.researchgroupid | COL0010477 | spa |
dc.relation.ispartofjournalabbrev | Rev. EIA. Esc. Ing. Antioq | spa |
Aparece en las colecciones: | Artículos de Revista en Ingeniería |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
LopezJesus_2014_CombinedOptimalReactivePower.pdf | Artículo de investigación | 763.45 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons