Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/38432
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorCardona Cardona, Eliana Cecilia-
dc.contributor.authorEscobar Restrepo, Julio Cesar-
dc.contributor.authorLatorre Correa, Federico-
dc.contributor.authorVillarraga Ossa, Junes Abdul-
dc.date.accessioned2024-03-03T03:05:42Z-
dc.date.available2024-03-03T03:05:42Z-
dc.date.issued2017-
dc.identifier.citationCardona Cardona, Eliana Cecilia, Escobar Restrepo, Julio Cesar, Latorre Correa, Federico, & Villarraga Ossa, Junes Abdul. (2017). Evaluación del Comportamiento de Dos Sistemas de Ajustes Uniendo Diente e Implante Asociados con una Prótesis Parcial Removible con Extensión Distal: Análisis de Elementos Finitos. International journal of odontostomatology, 11(3), 353-362. https://dx.doi.org/10.4067/S0718-381X2017000300353spa
dc.identifier.issn0718-3801-
dc.identifier.urihttps://hdl.handle.net/10495/38432-
dc.description.abstractRESUMEN: el propósito de esta investigación fue evaluar la distribución de esfuerzos bajo cargas verticales en la conexión diente-implante utilizando dos sistemas de ajustes, conectados a una protésis parcial removible (PPR) inferior por el método de elementos finitos (MEF). Usando los software CAD Solid Works 2010 y ANSYS versión 14 se diseñó, procesó y analizó el modelo tridimensional de una PPR inferior reemplazando 35, 36 y 37 soportada en mesial por coronas ferulizadas de 33 y 34 y en distal por un implante en posición de 37 (TaperedScrew-Vent® Zimmer). Se evaluaron dos sistemas de ajuste en la conexión diente –implante. Se midieron los valores de los esfuerzos von Mises sometiendo cada corona y diente de acrílico a cargas verticales desde los 200N con incrementos de 100N hasta los 800N, en ambos modelos no se observaron diferencias entre los valores von Mises en todas las estructuras y ante las cargas no hubo deformaciones permanentes. Estructuras como el hueso y el ligamento periodontal no presentaron valores von Mises altos, en ninguno de los modelos. La conexión diente-implante en ambos modelos, mostró una distribución de esfuerzos favorable al utilizar dos sistemas de ajustes asociados a una PPR, sometiéndola a diferentes niveles de carga en dirección verticaspa
dc.description.abstractABSTRACT: The aim of this study was to evaluate the behavior and stress distribution in the tooth-implant connection using two attachments systems associated with distal extension removable partial denture by finite element method (FEM). A rigid structure of mandible distal extension RPD was modeled and support by two different attachments, ERA-RV Sterngold® system in the first premolar and Locator, attachments Zest Anchors® on the implant 3.7 x 10 mm Tapered Screw-Vent® Zimmer located at the second molar. Two models were designed, one with a tooth-implant connection using a rigid attachment system in the tooth and resilient attachment on the implant and the other with a resilient system for both structures. The behavior was evaluated with loads of 200 N to 800 N in the vertical direction. No differences were observed in both models in all structures with respect to the values of von Mises and there were not permanents deformations on them. Furthemore, structures as bone and periodontal ligament were not affected in any models. The behavior of the tooth-implant connection in both models showed a favorable stress distribution using two attachments systems associated with RPD, subjecting it to different loads in the vertical direction.spa
dc.format.extent10 páginasspa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.publisherUniversidad de La Frontera, Facultad de Medicinaspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc/2.5/co/*
dc.titleEvaluación del comportamiento de dos sistemas de ajustes uniendo diente e implante asociados con una prótesis parcial removible con extensión distal: análisis de elementos finitosspa
dc.title.alternativeEvaluation of the Behavior of Two Attachments Systems in the Tooth-Implant Connection Associated With a Distal Extension Removable Partial Denture: Finite Element Analysesspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGrupo de Diseño Mecánicospa
dc.identifier.doi10.4067/S0718-381X2017000300353-
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn0718-381X-
oaire.citationtitleInternational Journal of Odontostomatologyspa
oaire.citationstartpage353spa
oaire.citationendpage362spa
oaire.citationvolume11spa
oaire.citationissue3spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc/4.0/spa
dc.publisher.placeTemuco, Chilespa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.subject.decsDentadura Parcial Removible-
dc.subject.decsDenture, Partial, Removable-
dc.subject.decsImplantes Dentales-
dc.subject.decsDental Implants-
dc.subject.lembMétodo de elementos finitos-
dc.subject.lembFinite element method-
dc.subject.proposalDiente pilarspa
dc.description.researchgroupidCOL0086448spa
dc.subject.meshurihttps://id.nlm.nih.gov/mesh/D003832-
dc.subject.meshurihttps://id.nlm.nih.gov/mesh/D015921-
dc.relation.ispartofjournalabbrevInt. J. Odontostomatol.spa
Aparece en las colecciones: Artículos de Revista en Ingeniería

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
CardonaEliana_2017_EvaluacionComportamientoDosSistemas .pdfArtículo de investigación378.54 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons