Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/10495/41525
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Montoya Rendón, María Luisa | - |
dc.contributor.author | Zapata Saldarriaga, Patricia María | - |
dc.contributor.author | Correa Ochoa, Mauricio Andrés | - |
dc.date.accessioned | 2024-08-28T00:30:12Z | - |
dc.date.available | 2024-08-28T00:30:12Z | - |
dc.date.issued | 2013 | - |
dc.identifier.citation | Montoya Rendón, M, Zapata Saldarriaga, P y Correa Ochoa, M. (2013). Contaminación ambiental por pm10 dentro y fuera del domicilio y capacidad respiratoria en puerto nare, colombia. Revista de Salud Pública. | spa |
dc.identifier.issn | 0124-0064 | - |
dc.identifier.uri | https://hdl.handle.net/10495/41525 | - |
dc.description.abstract | RESUMEN: Objetivo Explorar la relación entre niveles de PM10 intra y extradomiciliario y la función pulmonar de los habitantes, corregimiento La Sierra, Puerto Nare, AntioquiaColombia. Materiales y Métodos Mediante encuesta y observación, se determinaron condiciones ambientales y del entorno inmediato de viviendas correspondientes a 124 habitantes a los cuales se había realizado el examen espirométrico; se monitorearon condiciones meteorológicas: temperatura, humedad relativa, precipitación, velocidad del viento y PM10 (24 horas) al interior y exterior de las casas. Resultados En el 50 % de las viviendas el PM10 interior (0,05mg/m3) fue <PM10 exterior (0,06 mg/m3), humedad relativa 79,08 %, pluviosidad 33,03 mm, temperatura 28,75˚C y velocidad del viento 0,91 m/s. El 25 % del VEF1 fue <74 %. La correlación PM10 interior y exterior fue positiva, 0,197 (p=0,029) y entre PM10 interior y velocidad del viento negativa -0,215 (p=0,017). Se encontró débil relación positiva entre el volumen espiratorio forzado y el PM10 interior y exterior. Discusión Los resultados sugieren que la contaminación interior de las viviendas proviene de las emisiones de automotores, combustión industrial, y vías destapadas. El PM10 disminuyó con el aumento de la lluvia, la humedad relativa y el viento. | spa |
dc.description.abstract | ABSTRACT: Objective Exploring the relationship between PM10 intra- and extra-domiciliary levels and the lung function of people living in La Sierra, Antioquia, Colombia. Materials and Methods A survey and field observations were used for determining the environmental conditions and the immediate household environment of 124 people who had taken a spirometric test. Meteorological conditions were monitored: temperature, relative humidity, rainfall, wind speed and PM10 (24 hours) within and outside the houses. Results Indoor PM10 (0.05 mg/m3) in 50 % of the houses was <outdoor PM10 (0.06 mg/m3); there was 79.08 % relative humidity, 33.03 mm rainfall, 28.75˚C and 0.91 m/s wind speed. 25% of forced expiratory volume in 1 second (FEV1) was<74 %. There was a positive correlationbetween indoor and outdoor PM10 (0.197: p=0.029) and a negative correlation between indoor PM10 and wind speed (-0.215: p=0,017). A weak positive relationship was found between FEV1 and indoor and outdoor PM10. DiscussionThe results suggested that indoor pollution came from automobile emission, industrial combustionand unpaved roads (i.e. producing a lot of dust). PM10 decreased with increasing rain fall, higher relative humidity and increased wind speed. | spa |
dc.format.extent | 13 páginas | spa |
dc.format.mimetype | application/pdf | spa |
dc.language.iso | spa | spa |
dc.publisher | Universidad Nacional de Colombia, Facultad de Medicina, Instituto de Salud Pública | spa |
dc.type.hasversion | info:eu-repo/semantics/publishedVersion | spa |
dc.rights | info:eu-repo/semantics/openAccess | spa |
dc.rights.uri | http://creativecommons.org/licenses/by/2.5/co/ | * |
dc.subject.mesh | Material Particulado | - |
dc.subject.mesh | Particulate Matter | - |
dc.subject.mesh | Contaminación Ambiental | - |
dc.subject.mesh | Environmental Pollution | - |
dc.subject.mesh | Contaminación del Aire | - |
dc.subject.mesh | Air Pollution | - |
dc.subject.mesh | Salud Pública | - |
dc.subject.mesh | Public Health | - |
dc.title | Contaminación ambiental por PM10 dentro y fuera del domicilio y capacidad respiratoria en Puerto Nare, Colombia | spa |
dc.title.alternative | PM10 environmental pollution in and around housing and respiratory capacity in Puerto Nare, Colombia | spa |
dc.type | info:eu-repo/semantics/article | spa |
dc.publisher.group | Grupo de Ingeniería y Gestión Ambiental (GIGA) | spa |
dc.publisher.group | Salud y Ambiente | spa |
oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | spa |
dc.rights.accessrights | http://purl.org/coar/access_right/c_abf2 | spa |
dc.identifier.eissn | 2539-3596 | - |
oaire.citationtitle | Revista de Salud Pública | spa |
oaire.citationstartpage | 103 | spa |
oaire.citationendpage | 115 | spa |
oaire.citationvolume | 15 | spa |
oaire.citationissue | 1 | spa |
dc.rights.creativecommons | https://creativecommons.org/licenses/by/4.0/ | spa |
dc.publisher.place | Bogotá, Colombia | spa |
dc.type.coar | http://purl.org/coar/resource_type/c_2df8fbb1 | spa |
dc.type.redcol | https://purl.org/redcol/resource_type/ART | spa |
dc.type.local | Artículo de investigación | spa |
dc.description.researchgroupid | COL0016049 | spa |
dc.subject.meshuri | https://id.nlm.nih.gov/mesh/D052638 | - |
dc.subject.meshuri | https://id.nlm.nih.gov/mesh/D004787 | - |
dc.subject.meshuri | https://id.nlm.nih.gov/mesh/D000397 | - |
dc.subject.meshuri | https://id.nlm.nih.gov/mesh/D011634 | - |
dc.relation.ispartofjournalabbrev | Rev. Salud Pública. | spa |
Aparece en las colecciones: | Artículos de Revista en Ingeniería |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
MontoyaMaria_2013_ContaminacionAmbientalPm10.pdf | Artículo de investigación | 350.83 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons