Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/10495/4180
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Amell Arrieta, Andrés Adolfo | - |
dc.contributor.author | Cadavid Sierra, Francisco Javier | - |
dc.contributor.author | Pareja Restrepo, Jhon Alexánder | - |
dc.date.accessioned | 2016-08-23T13:26:56Z | - |
dc.date.available | 2016-08-23T13:26:56Z | - |
dc.date.issued | 2007 | - |
dc.identifier.citation | I. C. Bedoya, A. A. Arrieta, F. J. Cadavid y J. A. Pareja, "Efecto del grado de carga y la cantidad del combustible piloto en el comportamiento mecánico ambiental de un motor dual diesel-biogás para generación de electricidad," Rev. Fac. Ing. Univ. Antioquia, no. 42, pp. 79-93, 2007. | spa |
dc.identifier.issn | 0120-6230 | - |
dc.identifier.uri | http://hdl.handle.net/10495/4180 | - |
dc.description.abstract | RESUMEN: En este trabajo se presentan los resultados obtenidos en la caracterización mecánica y ambiental de un motor de encendido por compresión (MEC) para generación de electricidad, operando con diesel y en modo dual diesel-biogás. El motor ha sido acoplado a un generador eléctrico y evaluado a un régimen de 1.800 rpm con varios grados de carga, el biogás se ha simulado con una composición típica de 60% metano (CH4) y 40% de dióxido de carbono (CO2). Se han encontrado disminuciones en la eficiencia efectiva al reducir la cantidad de combustible piloto en modo dual, al igual que aumentos considerables en las emisiones de CH4 y monóxido de carbono (CO), la opacidad del humo no varía significativamente en modo dual, pero muestra una reducción drástica al compararla con las medidas para el motor en modo diesel. Los resultados obtenidos confirman la importancia del uso del biogás como alternativa para mecanismos de desarrollo limpio y como aporte a la disminución de la dependencia energética y económica de los combustibles fósiles. | spa |
dc.description.abstract | ABSTRACT: In this paper, analysis of the mechanical and environmental performances of a compression ignition engine working with diesel-biogas as fuels is carried out. The engine has been coupled to an electricity generator and tested at a constant speed of 1800 rpm for different loads. The biogas has been simulated from a mixture of methane and carbon dioxide with a fraction of 60% and 40% by volume, respectively. Decreases of the thermal efficiency as well as important increases in methane and carbon monoxide emissions in dual-fuel operation were found when the quantity of pilot fuel was reduced. Opacity varied slightly in dual-fuel operation. However, opacity presented a hard reduction in dual fuel operation with respect to diesel operation. Results validate the importance of using biogas as an alternative for Clean Development Mechanisms and a way to reduce economic fossil fuel dependency. | spa |
dc.format.extent | 14 | spa |
dc.format.mimetype | application/pdf | spa |
dc.language.iso | spa | spa |
dc.publisher | Universidad de Antioquia, Facultad de Ingeniería | spa |
dc.type.hasversion | info:eu-repo/semantics/publishedVersion | spa |
dc.rights | Atribución-NoComercial-CompartirIgual 2.5 Colombia (CC BY-NC-SA 2.5 CO) | * |
dc.rights | info:eu-repo/semantics/openAccess | spa |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/2.5/co/ | * |
dc.subject | Motor dual | - |
dc.subject | Biogás | - |
dc.subject | Aceite de palma | - |
dc.subject | Emisión de gases | - |
dc.subject | Combustible biodiésel | - |
dc.title | Efecto del grado de carga y la cantidad del combustible piloto en el comportamiento mecánico ambiental de un motor dual diesel-biogás para generación de electricidad | spa |
dc.title.alternative | Effect of the engine load level and pilot fuel quantity on the mechanical and environmental perfomance of a dual-fuel compression ignition engine in power generation | spa |
dc.type | info:eu-repo/semantics/article | spa |
dc.publisher.group | Ciencia y Tecnología del Gas y Uso Racional de la Energía (GASURE) | spa |
oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | spa |
dc.rights.accessrights | http://purl.org/coar/access_right/c_abf2 | spa |
dc.identifier.eissn | 2422-2844 | - |
oaire.citationtitle | Revista Facultad de Ingeniería Universidad de Antioquia | spa |
oaire.citationstartpage | 79 | spa |
oaire.citationendpage | 93 | spa |
oaire.citationissue | 42 | spa |
dc.rights.creativecommons | https://creativecommons.org/licenses/by-nc-sa/4.0/ | spa |
dc.publisher.place | Medellín, Colombia | spa |
dc.type.coar | http://purl.org/coar/resource_type/c_2df8fbb1 | spa |
dc.type.redcol | https://purl.org/redcol/resource_type/ART | spa |
dc.type.local | Artículo de investigación | spa |
dc.relation.ispartofjournalabbrev | Rev. Fac. Ing. Univ. Antioquia | spa |
Aparece en las colecciones: | Artículos de Revista en Ingeniería |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
BedoyaIvan_2007_CargaCombustibleElectricidad.pdf | Artículo de investigación | 2 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons