Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/4807
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorEchavarría Velásquez, Alejandro Iván-
dc.contributor.authorGómez, Gabriel Jaime-
dc.contributor.authorArismendi Echavarría, Jorge Alberto-
dc.date.accessioned2016-10-06T02:07:16Z-
dc.date.available2016-10-06T02:07:16Z-
dc.date.issued2008-
dc.identifier.citationP. Castaño, A. I. Echavarría, G. J. Gómez, and J. Arismendi, "Evaluación de la corrosión galvánica en amalgamas dentales de alto contenido de cobre por medio de técnicas electroquímicas", Rev. Fac. Ing. Univ. Antioquia, no. 45, pp. 77-86, 2008.spa
dc.identifier.issn0120-6230-
dc.identifier.urihttp://hdl.handle.net/10495/4807-
dc.description.abstractRESUMEN: En este trabajo se evaluó la corrosión galvánica de tres amalgamas dentales de alto contenido de cobre, una nacional Nu Alloy®dp (New Stetic) y dos importadas Contour®TM (Kerr, USA) y GS-80® (SDI, Australia), interactuando galvánicamente y en un diseño in Vitro con los siguientes materiales metálicos de uso odontológico: Titanio CP, Ti-6Al-4V tipo COC®, IPS d.sign 15® (Ni-CrMo) e IPS d.sign 91® (Au-Pd). Con la técnica electroquímica Amperometría de resistencia cero, se midió la evolución de las corrientes galvánicas en el tiempo. También se elaboraron curvas de polarización cíclicas para caracterizar electroquímicamente las amalgamas dentales y medidas del potencial a circuito abierto para analizar la nobleza o actividad de ellas en el medio de estudio. Los ensayos se realizaron por triplicado, en una celda de tres electrodos y utilizando como electrólito la solución fisiológica artificial de Ringer, desaireada y a 37 ± 1°C. De los resultados, se concluyó que en comparación a las amalgamas importadas, la amalgama nacional tiene la misma tendencia a sufrir corrosión galvánica bajo las condiciones de ensayo. Con el método estadístico ANOVA de una sola vía, se comprobó la similitud en el comportamiento electroquímico de las tres amalgamas dentales.spa
dc.description.abstractABSTRACT: The galvanic interaction between three high copper dental amalgams with another four dental metallic materials, was evaluated. The dental amalgams were: a national Nu Alloy®dp (New Stetic) and two imported Contour®TM (Kerr, USA) and GS-80® (SDI, Australia). The dental metallic materials were: Titanium CP, Ti-6Al-4V type COC®, IPS d.sign 15® (Ni-Cr-Mo) and IPS d.sign 91® (Au-Pd). The evolution of the galvanic currents with time was measured using a Zero Resistance Ammeter equipment. The dental amalgams were characterized by means of Polarization Cyclical Measurements, and the evolution of the open circuit potentials of the dental amalgams allowed analyzing the nobility or activity of the amalgams in the test mean. The tests were done by triplicate in a three electrode cell and using the artificial physiological solution of Ringer as the electrolyte, the solution was deaerated at 37 ± 1°C. Under the test conditions, it is concluded that the home amalgam has the same tendency to undergo galvanic corrosion as comparison to imported amalgams. Using statistical ANOVA method of a single via it was corroborated the same electrochemical behavior of dental amalgams.spa
dc.format.extent9spa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.publisherUniversidad de Antioquia, Facultad de Ingenieríaspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsAtribución-NoComercial-CompartirIgual 2.5 Colombia (CC BY-NC-SA 2.5 CO)*
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/2.5/co/*
dc.subjectAmalgama dental-
dc.subjectCorrosión-
dc.subjectCorrosión galvánica-
dc.titleEvaluación de la corrosión galvánica en amalgamas dentales de alto contenido de cobre por medio de técnicas electroquímicasspa
dc.title.alternativeEvaluation of the galvanic corrosion of high copper dental amalgams by means of electrochemical techniquesspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupCentro de Investigación, Innovación y Desarrollo de Materiales (CIDEMAT)spa
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn2422-2844-
oaire.citationtitleRevista Facultad de Ingeniería Universidad de Antioquiaspa
oaire.citationstartpage77spa
oaire.citationendpage86spa
oaire.citationissue45spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-sa/4.0/spa
dc.publisher.placeMedellín, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.relation.ispartofjournalabbrevRev. Fac. Ing. Univ. Antioquiaspa
Aparece en las colecciones: Artículos de Revista en Ingeniería

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
CastanoPatricia_2008_EvaluacionCorrosionAmalgamas.pdfArtículo de investigación760.4 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons