dc.date.issued2013-
dc.identifier.citationL. E. Correa et al., "Evaluación del desempeño de aisladores de porcelana recubiertos con películas de dióxido de titanio para disminuir el ensuciamiento", Rev. Fac. Ing. Univ. Antioquia, no. 66, pp. 131-140, 2013.spa
dc.identifier.issn0120-6230-
dc.identifier.urihttp://hdl.handle.net/10495/5385-
dc.description.abstractRESUMEN: El ensuciamiento de aisladores eléctricos en servicio expuestos a la atmósfera constituyen un gran inconveniente para el sector eléctrico, debido a que en la superficie se deposita material de naturaleza orgánica e inorgánica, formando una capa que en presencia de humedad puede volverse conductora, produciendo diferentes fenómenos que podrían deteriorar las propiedades aislantes del elemento y finalmente conducir a la ruptura del mismo, afectando principalmente el suministro de la energía eléctrica. Actualmente se encuentra en fase de desarrollo un método que consiste en la aplicación de una película de dióxido de titanio para minimizar la acumulación de suciedad en los aisladores de porcelana sin afectar las propiedades eléctricas de los mismos. Se evaluó el desempeño de dos espesores diferentes (una y dos capas) de dicha película en aisladores de porcelana, para lo cual se realizaron pruebas de adherencia, ángulo de contacto, corriente de fuga, tensión de flameo en seco y ensayos de erosión en laboratorio. Finalmente, se evaluó el desempeño en aisladores en servicio en una torre de transmisión de energía. Los aisladores recubiertos exhiben un buen desempeño en las pruebas de laboratorio. Además, tras 5 meses de exposición en servicio en la línea de alta tensión energizada, se observa una disminución en el ensuciamiento.spa
dc.description.abstractABSTRACT: The soiling of in-service electrical insulators exposed to the atmosphere is a major problem in power transmission lines. Several inorganic and organic particulate materials are deposited on insulator surfaces forming a layer that could become conductive in the presence of moisture. This produces different phenomena that could deteriorate the insulating properties of the material and eventually lead to its rupture, affecting the electrical energy supply. Currently, a method based in the application of a titanium dioxide film is being developed. This method tries to minimize the pollution accumulation on the porcelain insulators without affecting their electrical properties. In this work the performance of two different thicknesses of the coating film on the porcelain insulators was evaluated by means of contact angle, adhesion, leakage current, dry-flashover voltage and erosion laboratory tests. Finally, the in-service behavior of coated and no-coated insulators installed in a power transmission tower was evaluated. The coated insulators showed a good performance in the laboratory tests. Moreover, before 5 months of exposure in the energized power line, a decrease in the soiling was observed.spa
dc.format.extent9spa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.publisherUniversidad de Antioquia, Facultad de Ingenieríaspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsAtribución-NoComercial-CompartirIgual 2.5 Colombia (CC BY-NC-SA 2.5 CO)*
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/2.5/co/*
dc.subjectAisladores eléctricos-
dc.subjectSector eléctrico - América Latina - Aspectos ambientales-
dc.subjectDióxido de titanio-
dc.subjectMedición de espesores-
dc.titleEvaluación del desempeño de aisladores de porcelana recubiertos con películas de dióxido de titanio para disminuir el ensuciamientospa
dc.title.alternativePerformance evaluation of ceramic insulators coated with titanium dioxide films to reduce soilingspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupCentro de Investigación, Innovación y Desarrollo de Materiales (CIDEMAT)spa
dc.publisher.groupGrupo de Manejo Eficiente de la Energía (GIMEL)spa
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn2422-2844-
oaire.citationtitleRevista Facultad de Ingeniería Universidad de Antioquiaspa
oaire.citationstartpage131spa
oaire.citationendpage140spa
oaire.citationissue66spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-sa/4.0/spa
dc.publisher.placeMedellín, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.relation.ispartofjournalabbrevRev. Fac. Ing. Univ. Antioquiaspa
Aparece en las colecciones: Artículos de Revista en Ingeniería

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
CorreaLorena_2013_EvaluaciónDesempeñoAisladores.pdfArtículo de investigación700.59 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons