Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/7665
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorDuque Vallejo, Sara Isabel-
dc.contributor.authorOchoa Gómez, John Fredy-
dc.contributor.authorHernández Valdivieso, Alher Mauricio-
dc.date.accessioned2017-07-17T14:11:00Z-
dc.date.available2017-07-17T14:11:00Z-
dc.date.issued2017-
dc.identifier.citationA. F. Botero, S. I. Duque, J. F. Ochoa and A. M. Hernández, "Touchless control module for diagnostic images at the surgery room using the Leap Motion system and 3D Slicer Software", Rev. Fac. Ing. Univ. Antioquia, no. 82, p. 40-46, 2017. DOI: 10.17533/udea.redin.n82a05spa
dc.identifier.issn0120-6230-
dc.identifier.urihttp://hdl.handle.net/10495/7665-
dc.description.abstractRESUMEN: Durante los procedimientos quirúrgicos es importante que el personal (cirujanos, residentes o asistentes) interactúe con el paciente, evitando cualquier contacto físico con equipo y materiales que pudieron no ser esterilizados apropiadamente. Esto se hace con el fin de evitar al paciente infecciones y complicaciones posteriores a la cirugía. Con el aumento de la disponibilidad de imágenes diagnósticas esta herramienta se ha hecho cada vez más indispensable en los quirófanos, pero no siempre es posible mantener el control de asepsia de los equipos informáticos en los cuales se ejecutan los programas de visualización, factor que dificulta el acceso al personal asistencial a la información contenida en las imágenes. En este trabajo se presenta el desarrollo de un sistema que permite manipular un programa de visualización de imágenes diagnósticas mediante gestos evitando que el cirujano tenga contacto directo con la computadora. El sistema, que requiere una computadora con el software 3D-Slicer y el dispositivo Leap Motion, permite mediante gestos realizados con las manos acceder a operaciones básicas como el movimiento entre cortes de un volumen, cambio del tamaño de la imagen y cambio del plano anatómico de visualización, operaciones que para el cirujano son esenciales para la ubicación espacial y la toma de decisiones.spa
dc.description.abstractABSTRACT: During surgical procedures, it is important that the personnel (surgeon, residents, or assistants) interact with the patient avoiding any physical contact with equipment and materials that might have not been appropriately sterilized. This is done in order to prevent patient’s infections and complications after surgery. With the increased availability of diagnostic images, this technology has become indispensable in operating rooms but to maintain asepsis control of computer equipment on which the visualization programs are executed is not always possible, hindering access to personnel to information contained in the images. This paper describes the development of a system that allows the personnel to manipulate a medical imaging display program using gestures, avoiding the surgeon or the nurse to have a direct contact with the computer. The system, which requires a computer with 3D-Slicer software and Leap Motion (LM) device, allows through gestures made with the hands, to access the basic operations such as the movement between sections of a volume, to change the image size and the anatomical plane visualization; operations that are essential to the surgeon for the spatial location and decision making.spa
dc.format.extent6spa
dc.format.mimetypeapplication/pdfspa
dc.language.isoengspa
dc.publisherUniversidad de Antioquia, Facultad de Ingenieríaspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsAtribución-NoComercial-CompartirIgual 2.5 Colombia (CC BY-NC-SA 2.5 CO)*
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/2.5/co/*
dc.subjectImágenes diagnósticas-
dc.subjectModelo LEAP-
dc.subjectInteracción hombre máquina-
dc.subjectNeurocirugía-
dc.subjectGPS (Sistema de Posicionamiento Global)-
dc.subjectDiagnostic imaging-
dc.titleTouchless control module for diagnostic images at the surgery room using the Leap Motion system and 3D Slicer Softwarespa
dc.title.alternativeMódulo para el control sin contacto de imágenes diagnósticas en la sala de cirugía con el sistema Leap Motion y el Software 3D Slicerspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGrupo de Investigación en Bioinstrumentación e Ingeniería Clínica (GIBIC)spa
dc.identifier.doi10.17533/udea.redin.n82a05-
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn2422-2844-
oaire.citationtitleRevista Facultad de Ingeniería Universidad de Antioquiaspa
oaire.citationstartpage40spa
oaire.citationendpage46spa
oaire.citationissue82spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-sa/4.0/spa
dc.publisher.placeMedellín, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.relation.ispartofjournalabbrevRev. Fac. Ing. Univ. Antioquiaspa
Aparece en las colecciones: Artículos de Revista en Ingeniería

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
BoteroAndres_2017_TouchlessControlModule.pdfArtículo de investigación1.39 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons