Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/9387
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorRevelo Basante, Servio Hames-
dc.contributor.authorMendoza Mendoza, Heydy Lorena-
dc.contributor.authorMachado Reyes, Malka Irina-
dc.date.accessioned2018-04-20T14:13:56Z-
dc.date.available2018-04-20T14:13:56Z-
dc.date.issued2017-
dc.identifier.citationRevelo Basante, S. Mendonza Mendoza, H. Machado Reyes, M. Síndrome Edificio Enfermo (SEE), Facultad Nacional De Salud Pública. [Trabajo de grado de especialización]. Medellín, Colombia: Universidad de Antioquia; 2017.spa
dc.identifier.urihttp://hdl.handle.net/10495/9387-
dc.description.abstractRESUMEN: Objetivo: El Síndrome de Edificio Enfermo (SEE) es un conjunto de síntomas derivados de factores ambientales con incidencia de estos en las personas. El propósito de este trabajo fue identificar los factores de riesgo que pueden conllevar a la aparición del SEE en la Facultad Nacional de Salud Pública FNSP de la Universidad de Antioquia. Metodología: Investigación descriptiva, empleando cuestionario NTP 290 del Ministerio de Trabajo y Asuntos Sociales de España. Se suministraron 178 cuestionarios al personal de la FNSP obteniendo 86 diligenciados, con variables del entorno y posibles síntomas. Además, mediciones de factores de riesgo ruido, iluminación y temperatura. Resultados: La población tiene un rango de edad entre 21 a 73 años. De acuerdo a las mediciones ambientales el nivel de ruido se encuentra dentro de los valores recomendados, a pesar que el 95% de las personas manifestaron sentir ruido en su puesto de trabajo, causado por conversaciones y sistemas de ventilación. El 96% de puestos de trabajo evaluados en iluminación presentan al menos en uno de los tres puntos medidos, valores por debajo de los niveles recomendados. En temperatura, el 97,67% de las oficinas mantienen un ambiente ligeramente caliente y el 2,33% confortable. Conclusiones: Se encontraron algunos factores del SEE como falta de ventilación, ruido, problemas de iluminación y ambiente de trabajo no confortables, donde los principales síntomas que se manifestaron son dolor de cabeza, aletargamiento/falta de energía, insomnio, enrojecimiento ocular, entre otros, que pudieran indicar que en la FNSP posiblemente se encuentre afectado por SEE.spa
dc.description.abstractABSTRACT: Objective: Sick Building Syndrome (ESS) is a set of symptoms derived from environmental factors with an incidence of these in people. The purpose of this study was to identify the risk factors that can lead to the emergence of ESS in the National School of Public Health FNSP of the University of Antioquia. Methodology: Descriptive research, using questionnaire NTP 290 of the Ministry of Labor and Social Affairs of Spain. 178 questionnaires were provided to the FNSP staff obtaining 86 completed, with environmental variables and possible symptoms. In addition, measurements of risk factors noise, illumination and temperature. Results: The population has a age range between 21 and 73 years. According to environmental measurements, the noise level is within the recommended value, although 95% of people reported feeling noise at work, caused by conversations and ventilation systems. The 96% of jobs evaluated in lighting have at least one of the three measured points, values below the recommended levels. In temperature, 97.67% of the offices maintain a slightly warm atmosphere and 2.33% comfortable. Conclusions: Some factors of the ESS were found as lack of ventilation, noise, illumination problems and a non-comfortable work environment, where the main symptoms that manifested were headache, lethargy / lack of energy, insomnia, eye redness, among others, Which could indicate that the FNSP may be affected by SBSspa
dc.format.extent15spa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.type.hasversioninfo:eu-repo/semantics/acceptedVersionspa
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO)*
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.5/co/*
dc.titleSíndrome edificio enfermo (SEE), Facultad Nacional de Salud Públicaspa
dc.title.alternativeSick building syndrome (ESS), National Faculty of Public Healthspa
dc.typeinfo:eu-repo/semantics/preprintspa
dc.description.noteArtículo de Trabajo de Grado de Especialización en Salud Ocupacionalspa
oaire.versionhttp://purl.org/coar/version/c_ab4af688f83e57aaspa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
thesis.degree.nameEspecialista en Salud Ocupacionalspa
thesis.degree.levelEspecializaciónspa
thesis.degree.disciplineFacultad Nacional de Salud Pública. Especialización en Salud Ocupacionalspa
thesis.degree.grantorUniversidad de Antioquiaspa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-nd/4.0/spa
dc.publisher.placeMedellín, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_46ecspa
dc.type.localTesis/Trabajo de grado - Monografía – Especializaciónspa
dc.subject.decsSalud pública-
dc.subject.decsPublic health-
dc.subject.decsFactores de riesgo-
dc.subject.decsRisk factors-
dc.subject.decsPerception-
dc.subject.decsPercepción-
dc.subject.proposalSíndrome edificio enfermo (SEE)spa
Aparece en las colecciones: Especializaciones de la Facultad Nacional de Salud Pública

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
ReveloServio_2017_SíndromeEdificioEnfermo.pdfTrabajo de grado de especialización477.69 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons