Escudo Universidad de Antioquia

Sistema de Bibliotecas

Universidad de Antioquia

Repositorio Institucional UdeA


Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10495/9708
Título : Assessment of toxicity in industrial wastewater treated by biological processes using luminescent bacteria
Otros títulos : Evaluación de la toxicidad en aguas residuales industriales tratadas por procesos biológicos utilizando bacterias luminiscentes
Autor : Rodríguez Loaiza, Diana Catalina
Ramírez Henao, Omaira
Peñuela Mesa, Gustavo Antonio
Palabras clave : Materia orgánica
Organic matter
Toxicidad
Toxicity
Nitrógeno amoniacal
Ammonia nitrogen
Fecha de publicación : 2016
Editorial : Universidad de Antioquia
Instituto de Biología
Citación : Rodríguez D, Rodríguez O, Peñuela G. 2016. Assessment of toxicity in industrial wastewater treated by biological processes using luminescent bacteria. Actualidades Biológicas. (105): 211-216. DOI: 10.17533/udea.acbi.v38n105a08
Resumen: La toxicidad de las aguas residuales provenientes de empresas de procesamiento de productos cárnicos fue evaluada antes y después del tratamiento usando un reactor secuencial por lotes (SBR). Las pruebas de toxicidad fueron evaluadas mediante el análisis del efecto inhibidor de muestras en relación con la emisión de luz a partir de bacterias marinas de la especie Vibrio scheri. Los resultados demostraron que los efluentes antes del tratamiento eran altamente tóxicos (EC50 < 60%), mientras que los resultados después del tratamiento mostraron baja o nula toxicidad (EC50 > 82%). En algunas etapas operativas del reactor SBR, se encontró correlación entre el nitrógeno amoniacal presente en cada muestra y la toxicidad de las aguas residuales tanto en el afluente y los efluentes, con correlaciones (R2) de 0,6141 y 0,8158, respectivamente. Como consecuencia de estos resultados, el sistema SBR puede ser considerado eficiente en la eliminación de materia orgánica y nitrógeno, y de ese modo disminuir la toxicidad en el agua tratada.
Abstract : The toxicity of wastewater from a meat by-products processing company was evaluated before and after treatment using the Sequencing Batch Reactor (SBR). Toxicity tests were carried out by analyzing the inhibitory effect of samples in relation to light emission from marine bacteria of the species Vibrio scheri. The results found that the efluuents prior to treatment were highly toxic (EC50 < 60%) whereas post-treatment results showed low or no toxicity (EC50 > 82%). In some operational stages of the SBR reactor, a high correlation between the ammonia nitrogen present in each sample and the toxicity of wastewater from both the in fluents and the efluents was found, with correlations (R2) of 0.6141 and 0.8158, respectively. As a consequence of these results, the SBR system can be considered ef cient at removing organic matter, and nitrogen, and thereby decreasing toxicity in treated water.
Grupo de INV. : Diagnóstico y Control de la Contaminación
URI : http://hdl.handle.net/10495/9708
ISSN : 03043584
21457166 E
Aparece en las colecciones: CIEN (Centro de Investigaciones en Ciencias Exactas y Naturales)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
RodriguezLoaizaDiana_2016_ToxicityIndustrialWastewater.pdfArtículo de Revista1,74 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

 


Unidad de Gestión Tecnológica /Sistema de Bibliotecas / Universidad de Antioquia / Cl. 67 Nº 53 - 108 - Bloque 8 Conmutador: 219 51 51- 219 51 40 comunicacionessistemadebibliotecas@udea.edu.co Medellín - Colombia