Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/10495/5457
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorAguirre Ramírez, Néstor Jaime-
dc.date.accessioned2016-11-18T23:07:57Z-
dc.date.available2016-11-18T23:07:57Z-
dc.date.issued2013-
dc.identifier.citationY. Montoya and N. J. Aguirre, "Dinámica fisicoquímica de las aguas de un sistema de planicies inundables tropicales", Rev. Fac. Ing. Univ. Antioquia, no. 69, pp. 256-273, 2013.spa
dc.identifier.issn0120-6230-
dc.identifier.urihttp://hdl.handle.net/10495/5457-
dc.description.abstractRESUMEN: Se estudió el cambio de algunas variables fisicoquímicas en el agua de siete caños y siete ciénagas pertenecientes a la zona de planos de inundación de Ayapel en nueve muestreos durante el periodo 2006-2009. El valor medio de la conductividad eléctrica en la ciénaga es tres veces inferior al valor medio de las ciénagas de la región. 100 µS/cm puede considerarse como discriminante entre ciénagas con valores inferiores y los caños con valores superiores. No hubo relación entre la transparencia y la concentración de pigmentos fotosintéticos, lo que podría considerarse como indicador de un nivel de estado trófico bajo del sistema. A nivel temporal todas las formas de nutrientes evaluadas presentaron diferencias lo que indica la importancia del efecto del pulso de inundación a través del ciclo hidrológico. Con la disminución de la columna de agua en época de estiaje, se evidenció un aumento de las concentraciones de nitrógeno, las cuales se ven favorecidas por la resuspensión de material del fondo de la ciénaga. La concentración de fósforo es más sensible a la variación espacial, ya que el ciclo de este nutriente estuvo asociado a los sedimentos y a la composición del suelo de cada microcuenca. Se encontró que para una misma fase del pulso en ciclos sucesivos, se registran diferencias en la dinámica del sistema, por lo que el momento hidrológico en el que se realiza el muestreo es el factor principal en el comportamiento de las condiciones fisicoquímicas del sistema.spa
dc.description.abstractABSTRACT: We studied the physicochemical variables change in seven water swamps and seven streams outside the floodplain area Ayapel in nine samples during the period 2006-2009. The average value of electrical conductivity in the swamp is three times less than the value of the swamps of the region. 100 µS/cm can be considered as discriminating among swamps with lower values, and streams with higher values. There was no relationship between transparency and the concentration of photosynthetic pigments, which could be considered as an indicator a lower level trophic system. Temporary level all evaluated forms of nutrients present differences which indicates the importance of the effect of the pulse of flooding through the hydrological cycle. With the decline of the column of water in times of drought, there was an increase in the concentrations of nitrogen, which are favored by the resuspended material from the bottom of the swamp. Phosphorus concentration is most sensitive to spatial variation, this nutrient cycle is very associated with the sediments and the composition of the soil of each basin. We found that for the same phase in successive cycles of the pulse, there are differences in the system dynamics so that when the hydrologic sampling is performed is the main factor in the behavior of the physicochemical conditions of the system.spa
dc.format.extent17spa
dc.format.mimetypeapplication/pdfspa
dc.language.isospaspa
dc.publisherUniversidad de Antioquia, Facultad de Ingenieríaspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsAtribución-NoComercial-CompartirIgual 2.5 Colombia (CC BY-NC-SA 2.5 CO)*
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/2.5/co/*
dc.subjectVariables físico-químicas del agua-
dc.subjectConductividad eléctrica-
dc.subjectCiénaga de Ayapel - Córdoba (Colombia)-
dc.subjectVariabilidad espacial-
dc.titleDinámica fisicoquímica de las aguas de un sistema de planicies inundables tropicalesspa
dc.title.alternativePhysicochemical dynamics water in a tropical floodplainspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGeoLimnaspa
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn2422-2844-
oaire.citationtitleRevista Facultad de Ingeniería Universidad de Antioquiaspa
oaire.citationstartpage256spa
oaire.citationendpage273spa
oaire.citationissue69spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-sa/4.0/spa
dc.publisher.placeMedellín, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.relation.ispartofjournalabbrevRev. Fac. Ing. Univ. Antioquiaspa
Aparece en las colecciones: Artículos de Revista en Ingeniería

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
MontoyaYimmy_2013_DinamicaFisicoquimicaAguas.pdfArtículo de investigación2.46 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons