dc.identifier.citationI. C. Muñoz-Ortega, D. A. Urrego-Higuita, A. F. Vallejo-Aristizábal and A. M. Hernández-Valdivieso, "Device for simulation of restrictive pathologies in healthy subjects with non-invasive mechanical ventilation," Revista Facultad de Ingeniería, no. 86, pp. 19-26, 2018.spa
dc.identifier.issn0120-6230-
dc.identifier.urihttp://hdl.handle.net/10495/9564-
dc.description.abstractRESUMEN: La evaluación de la mecánica ventilatoria en pacientes ventilados mecánicamente permite ajustar su tratamiento en las unidades de cuidados intensivos en términos del ajuste del modo ventilatorio y sus parámetros asociados. Sin embargo, solo con maniobras obstructivas es posible estimar parámetros como la compliancia y la resistencia respiratorias en ventilación espontánea. Una de las limitaciones más importantes en el desarrollo de técnicas de estimación no obstructivas de la mecánica ventilatoria es que se trata de un sistema no estacionario y la variación de sus parámetros está sujeta a la variabilidad del patrón ventilatorio. Este artículo tiene como objetivo presentar y evaluar un dispositivo que permita modificar artificialmente la distensibilidad torácica de un sujeto sano, lo cual permitirá registrar en un futuro una base de datos útil para el desarrollo de técnicas de estimación de la mecánica ventilatoria. El dispositivo se conformó por una coraza, una bomba y un controlador que permite variar la presión al interior de la coraza, la cual fue ubicada en el pecho y abdomen de los voluntarios para cambiar la distensibilidad de manera controlada. 5 voluntarios participaron en la avaluación del dispositivo, consiguiendo cambios porcentuales de 34,5 ± 9,4% respecto a su valor en reposo para una presión de 10 cmH2O y cambios de 46,8 ± 5,7% para la máxima presión de 20 cmH2O. Se logró diseñar un dispositivo que permitiera modificar artificialmente la distensibilidad torácica de manera comparable para cualquier sujeto sano. Palabras claves: Mecánica ventilatoria, compliancia torácica, enfermedades restrictivas, sistemas de control.spa
dc.description.abstractABSTRACT: The respiratory mechanics assessment in patients with mechanical ventilation allows to adjust the treatment in intensive care units related to the ventilatory mode and parameters of mechanical ventilator settings. However, to estimate the compliance and respiratory resistance in spontaneous ventilation is only possible with obstructive maneuvers or invasive techniques. One of the most important limitations to develop new techniques for respiratory mechanics estimation is the non-stationary characteristic of the system and the variability of parameters according to the variability of the breathing pattern. The aim of this article is to present and evaluate a device that allows artificially modify the thoracic compliance of a healthy subject, which will make possible to register in the future a useful database for the development of techniques for estimating ventilatory mechanics. The device was formed by a cuirass, a pump and a controller that allows to vary the pressure inside the cuirass, which was placed in the chest and abdomen of the volunteers to change compliance in a controlled manner. 5 volunteers participated in the performance test of the device, achieving percentage changes of 34.5 ± 9.4% respecting their resting value for a pressure of 10 cmH2O and changes of 46.8 ± 5.7% for the maximum pressure of 20 cmH2O. It was possible to design a device that allowed to artificially modify thoracic compliance in a comparable way for any healthy subject. KEYWORDS: Respiratory mechanics, thoracic compliance, restrictive diseases, control systems.spa
dc.format.extent7spa
dc.format.mimetypeapplication/pdfspa
dc.language.isoengspa
dc.publisherUniversidad de Antioquia, Facultad de Ingenieríaspa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersionspa
dc.rightsAtribución-NoComercial-CompartirIgual 2.5 Colombia (CC BY-NC-SA 2.5 CO)*
dc.rightsinfo:eu-repo/semantics/openAccessspa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/2.5/co/*
dc.subjectPatología-
dc.subjectPathology-
dc.subjectRespiración artificial-
dc.subjectArtificial respiration-
dc.subjectRepiradores-
dc.subjectRespirators-
dc.subjectSistemas de control-
dc.titleDevice for simulation of restrictive pathologies in healthy subjects with non-invasive mechanical ventilationspa
dc.title.alternativeDispositivo para simulación de patologías restrictivas en sujetos sanos ventilados mecánicamente de manera no invasivaspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.publisher.groupGrupo de Investigación en Bioinstrumentación e Ingeniería Clínica (GIBIC)spa
dc.identifier.doi10.17533/udea.redin.n86a03-
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85spa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2spa
dc.identifier.eissn2422-2844-
oaire.citationtitleRevista Facultad de Ingeniería Universidad de Antioquiaspa
oaire.citationstartpage19spa
oaire.citationendpage26spa
oaire.citationissue86spa
dc.rights.creativecommonshttps://creativecommons.org/licenses/by-nc-sa/4.0/spa
dc.publisher.placeMedellín, Colombiaspa
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1spa
dc.type.redcolhttps://purl.org/redcol/resource_type/ARTspa
dc.type.localArtículo de investigaciónspa
dc.relation.ispartofjournalabbrevRev. Fac. Ing. Univ. Antioquiaspa
Aparece en las colecciones: Artículos de Revista en Ingeniería

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
MunozIsabel_2018_DeviceSimulationRestrictive.pdfArtículo de investigación3.27 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons