Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/10495/21375
Título : | Design of Malaria Diagnostic Criteria for the Sysmex XE-2100 Hematology Analyzer |
Autor : | Campuzano Zuluaga, Germán Álvarez Sánchez, Luis Gonzalo Escobar Gallo, Gloria Elcy Ríos Orrego, Alexandra Marcela Pabón Vidal, Adriana Lucía Miranda Arboleda, Andrés Felipe Blair Trujillo, Silvia Campuzano Maya, Germán |
metadata.dc.subject.*: | Malaria Diagnóstico Diagnosis Plasmodium vivax |
Fecha de publicación : | 2010 |
Editorial : | American Society of Tropical Medicine and Hygiene |
Citación : | Campuzano-Zuluaga, G., Álvarez-Sánchez, G., Escobar-Gallo, G. E., Valencia-Zuluaga, L. M., Ríos-Orrego, A. M., Pabón-Vidal, A., Miranda-Arboleda, A. F., Blair-Trujillo, S., & Campuzano-Maya, G. (2010). Design of Malaria Diagnostic Criteria for the Sysmex XE-2100 Hematology Analyzer, The American Society of Tropical Medicine and Hygiene, 82(3), 402-411. Retrieved Aug 1, 2021, from https://www.ajtmh.org/view/journals/tpmd/82/3/article-p402.xml |
Resumen : | Abstract: Thick film, the standard diagnostic procedure for malaria, is not always ordered promptly. A failsafe diagnostic strategy using an XE-2100 analyzer is proposed, and for this strategy, malaria diagnostic models for the XE-2100 were developed and tested for accuracy. Two hundred eighty-one samples were distributed into Plasmodium vivax, P. falciparum, and acute febrile syndrome groups for model construction. Model validation was performed using 60% of malaria cases and a composite control group of samples from AFS and healthy participants from endemic and non-endemic regions. For P. vivax, two observer-dependent models (accuracy = 95.3–96.9%), one non–observer-dependent model using built-in variables (accuracy = 94.7%), and one non–observer-dependent model using new and built-in variables (accuracy = 96.8%) were developed. For P. falciparum, two non–observer-dependent models (accuracies = 85% and 89%) were developed. These models could be used by health personnel or be integrated as a malaria alarm for the XE-2100 to prompt early malaria microscopic diagnosis. |
metadata.dc.identifier.eissn: | 1476-1645 |
ISSN : | 0002-9637 |
metadata.dc.identifier.doi: | https://doi.org/10.4269/ajtmh.2010.09-0464 |
Aparece en las colecciones: | Artículos de Revista en Ciencias Médicas |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
CampuzanoGerman_2010_MalariaSysmexHematology.pdf | Artículo de investigación | 2.31 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons